![Lupus Electronics LUPUSEC-XT1 Manual Download Page 99](http://html1.mh-extra.com/html/lupus-electronics/lupusec-xt1/lupusec-xt1_manual_1950353099.webp)
99
Wireless relay
Product description:
1.
Control LED
2.
Function switch
3.
Terminal clamps
4.
9 V jumper
5.
Buzzer
Scope of delivery:
1 x 9 V DC power supply unit
2 x Screws and dowels
1 x Attachment strip
1 x Data sheet / instructions
1 x Wireless relay manual
Put the wireless relay into operation
1.
Open the bottom of the wireless relay.
2.
Connect the supplied power supply unit (9 V DC) to the wireless relay.
3.
A blue switch bay with altogether seven switches is located on the right side. By
default, they are all set to OFF (down).
4.
The following table lists the functions of the switches:
SW1
Mode to add the relay to the control unit
OFF
Off
ON
On
SW2
Not occupied
SW3
SW4
Relay functions
ON
ON
ON with alarm until deactivated manually
ON
OFF
ON for 3 minutes with alarm or until deactivated manually
OFF
OFF
ON when arming/OFF when disarming
SW5
SW6
Alerting method
ON
ON
Perimeter alarm (burglary alarm)
OFF
ON
ON with fire alarm
ON
OFF
ON with water alarm
OFF
OFF
ON with all alarms
SW7
ON
Factory reset
5.
To put the wireless relay into operation, set SW1 to ON. The control lamp of the
wireless relay lights up briefly for confirmation.
6.
Start the control unit’s configuration page, open the menu “Sensors”
“Devices”
and click the item “Add/apply device”.
7.
The control unit should recognize the wireless relay and confirm this with a long
signal tone. If not, repeat step 5.