![Lupus Electronics LUPUSEC-XT1 Manual Download Page 88](http://html1.mh-extra.com/html/lupus-electronics/lupusec-xt1/lupusec-xt1_manual_1950353088.webp)
88
Water detector
Product description:
1.
Battery
2.
Test button
Put the water detector into operation
1.
Open the housing by unscrewing the two screws from the housing bottom.
2.
Install the supplied batteries.
3.
Start the XT1 configuration menu and open the menu “Sensors”
“Add”.
4.
Click „Start“.
5.
Press the Test button on the electronic component of the water detector.
6.
The XT1 configuration menu should indicate the water detector.
7.
Add the water detector.
Battery:
The water detector requires four alkaline batteries. The average battery life is approx.
3 years. The water detector sends the status to the control unit every 30 to 50
minutes. If the battery runs low, this is reported to the control unit immediately.
Installation:
1.
Remove the screws from the housing bottom.
2.
Drill through the two notches left for the screws, if you want e.g. to fasten it to the
wall.
3.
Mount the water detector the wall using the supplied screws.
4.
Place the water detector, which is at the end of the cable, at the location, where it
is intended to trigger water alarm, e.g. on the floor. If water forms a bridge
between the two pins, it triggers an alarm. Fix the sensor so that it cannot
accidentally shift.
5.
Close the housing and fix it with the screws.
Note:
In case of water contact, the water detector sends an alarm to the control unit twice
at a two-minute interval. If the water level falls again, the water detector returns to its
1
2