109
Manual test of connection between sensor and repeater:
1.
Use this function to test whether a sensor added to the repeater is already or still
connected to the repeater.
2.
Set SW2 to ON.
3.
Press the test (learn) button of the sensor, which was added already to the
repeater. If the connection to the repeater is available, the repeater will sound a
long signal tone and the red LED lights up for one second.
4.
After having tested the connection of all required sensors to the repeater, set
SW2 back to OFF.
Factory settings:
1.
Set SW3 to ON
2.
Press and keep pressed the (red) “Delete memory button” for at least 5 seconds.
A long signal tone sounds. This deletes all sensors and their
activation/connection to the XT1 control unit!
3.
Set SW3 back to OFF.
Note:
You can
not
use the following sensors/devices with the wireless repeater: PSS
devices (wireless sockets, in-wall relays), PIR network camera, temperature
sensors, wireless relays, wireless repeaters.
As long as a sensor learned to the repeater is able to transmit its signal strength
directly to the control unit, this (weaker) signal is shown in the web interface. You
can test the proper function of the sensor by increasing the sensor’s distance to
the control unit and performing a range test. If the signal strength now increases,
the sensor transmits via the repeater. In case of an alarm, the sensor will reach
the control unit one way or the other.