Note
:
If the tamper contact is disabled, the siren does not transmit status updates to the
control unit anymore for as long as it is disabled. For that time, you can also not see
the current state of the tamper contact via Sensors
List.
Caution!
If you open the siren without deactivating the tamper contact before, the audio alarm
of the siren will be activated even if the siren is not integrated in the control unit
anymore! In that case, you should wear ear protection and disconnect the power
supply as quickly as possible.
Confirmation signal on/off (in Arm/Disarm)
With this function active, the siren will sound one signal tone when arming and
two signal tones when disarming.
To disable the confirmation signal of the siren(s) upon arming/disarming,
proceed as follows:
o
Click “Confirmation signal off”.
o
Then click on “Apply to siren” below.
Note:
If the tamper contact of the siren is open when arming the system, five short acoustic
signals sound even though the confirmation signal is disabled.
Entrance signal on/off
With this function active, the siren will sound confirmation signals for the
duration of the defined delay until the system is armed.
To disable the warning signal of the siren(s) upon entry/exit, proceed as
follows:
o
Click “Entrance signal”
“Off”
o
Then click “OK” below
Note:
These three settings are transmitted only and not permanently stored in this
menu. After they were transmitted, all three settings are ON again - but they were
stored in the sirens, after they transmitted the confirmation signal.
In addition, please note that the configuration is transmitted to all currently
connected and active external sirens. If you want to
configure several sirens
differently
, you should add these sirens later or just disconnect these sirens
from the power supply temporarily. It is impossible to read out the current siren
configuration.