255-700-447
7-19
PacketStar
®
PSAX 2300 Multiservice Media Gateway User Guide
, Issue 1
Release 9.0.0
Chapter 7 Configuring ATM Trunking
Adding a Bearer VCC Identifier
[VCC Interface
ID]
Default: 00/00/00
Range: N/A
Format: Numeric
Identifies the VCC interface ID for the outgoing interface.
The trunk bearer VCC does not become active until both
the local and remote trunk terminations are configured
and brought into service. After this is done, the values
assigned to the trunk are displayed in this field and the
VCC VPI/VCI field below. This field is valid only when
Pvc is selected in the VCC Conn Type field.
[VCC VPI/VCI]
Default: 0 / 0
Range: 0–4095
(VPI); 0–65535
(VCI)
Format: Numeric
Identifies the VPI and VCI for the outgoing interface. The
trunk bearer VCC does not become active until both the
local and remote trunk terminations are configured and
brought into service. After this is done, the values
assigned to the trunk are displayed in this field and the
VCC Interface ID field above. This field is valid only when
Pvc is selected in the VCC Conn Type field.
[VCC
VIB/VUNIB]
Default: 0/0
Range: N/A
Format: Numeric
Specifies the egress part of the A to B side of the VI/VUNI.
This field is valid only when Pvc is selected in the VCC
Conn Type field.
[VCC Owner]
Default: Local
Range: N/A
Format: Predefined
Indicates whether the bearer VCC owner is the active
(local) side or the passive (remote) side of the connec-
tion. If the values are improperly set, the bearer VCC will
not
become active.
This field is valid only when Spvc or Pvc is selected in
the VCC Conn Type field.
Local
The VCC owner is local.
Wireless backhaul applications:
Select this VCC Owner
Type for the cell site (caller) side of the connection.
Remote
The VCC owner is remote.
Wireless backhaul applications:
Select this VCC Owner
Type for the MSC (called) side of the connection.
[Retry
Timer/Limit]
Default: 30/0
Range:
Format: Numeric
Timer: Specifies the amount of time(seconds) to wait
before attempting to establish the signaling side of the
connection after a previously failed call attempt. The
value 0 indicates that the call attempt is to be retried
immediately.
Limit: Specifies the maximum limit on how many retried
calls are to be attempted. The value 0 indicates no limit
on how many call attempts can be made. This field is
valid only when Spvc is selected in the VCC Conn Type
field.
Wireless backhaul applications:
On
active
(local) side
SPVCs, this is a configurable parameter.
Table 7-14. Field Descriptions for the ATM Trunking Bearer VCC Configuration Window
*
(Continued)
Field Name
Field Values
Description