255-700-447
5-71
PacketStar
®
PSAX 2300 Multiservice Media Gateway User Guide
, Issue 1
Release 9.0.0
Chapter 5 Site-Specific Configuration
Using the Equipment Configuration Window
Using the Equipment Configuration Window
This section describes how to obtain product, model, version, and serial num-
ber data about a module from the Equipment Configuration window. In
addition, the window provides operational status and alarm conditions on
each installed module. You also use this window to access the port and chan-
nel configuration windows for the PSAX modules.
Directory
Default: None
Range: N/A
Format: Alphanumeric
Specifies the directory pathname on the network
server to which the PSAX system will send the bulk
statistics. Enter a directory pathname no longer
than 79 characters in length. You must have
already set up this directory pathname on the net-
work server.
Collection Time
Period
Default: 60
Range: 60–1440
Format: Numeric (min-
utes)
Specifies the frequency (in minutes) at which bulk
statistics will be collected and sent to the network
server. Enter a value in increments of 60 minutes,
such as, 60, 120, 180 and so on up to 1440. For
example, if you choose every 60 minutes, the PSAX
system will send the collected bulk statistics to the
network server at the beginning of every hour:
12:00 am, 1:00 am, 2:00 am, and so on.
[Operation Status]
Default: Inactive
Range: N/A
Format: Predefined
Displays the current operational status of the trans-
mission of bulk statistics files via FTP to the network
server.
Inactive
Indicates that the PSAX system is
not
currently
sending bulk statistics file to the network server.
InProgress
Indicates that the PSAX system is currently sending
bulk statistics file via FTP to the network server.
Successful
Indicates that the most recent bulk statistics file was
sent successfully to the network server.
Failed
Indicates that the PSAX system could not success-
fully send the bulk statistics file to the network
server due to an FTP or another type of error.
[Max Usage]
Default: 1000
Range: 0–1000
Format: Numeric
Displays the maximum number of bulk statistics
records the PSAX system can support for collecting
ATM and frame relay interface statistics and ATM
and frame relay PVC connection statistics.
[Current Usage]
Default: 0
Range: 0–1000
Format: Numeric
Displays the number of bulk statistics records cur-
rently being collected including ATM and frame
relay interface statistics and ATM and frame relay
connection statistics.
Table 5-36. Field Descriptions for the Bulk Statistics Configuration Window (Continued)
Field Name
Field Values
Description