Chapter 13 Upgrading PSAX System Software
Manually Selecting I/O and Server Module Firmware Drivers
A firmware driver is a binary file used to initialize (boot) an I/O or a server
module. The two types of drivers are the default driver and a nondefault
(configurable) driver. The PSAX system selects the default driver when the
I/O or server module boots for the first time after it is inserted into the PSAX
chassis.
Manually selecting a different firmware driver (other than the default driver)
for an I/O or a server module includes the following tasks:
•
“Accessing the Firmware Version Control Window”
•
“Selecting a Firmware Driver”
•
“Downloading a Firmware Driver”
Accessing the Firmware Version Control Window
To access the Firmware Version Control window on which you change or
update firmware drivers for I/O and server modules, perform the steps in the
following procedure.
Begin
1
On the Console Interface Main Menu window (see Figure 13-7), select
the Software Version Configuration option.
The Software Version Configuration window is displayed.
2
On the Software Version Configuration window (see Figure 13-8), select
the Firmware Version Control option.
The Firmware Version Control window is displayed.
Figure 13-7. Console Interface Main Menu Window (Software Version
Configuration Option Selected)