Chapter 7 Configuring ATM Trunking
Adding a Signaling VCC Identifier
7-8
255-700-447
PacketStar
®
PSAX 2300 Multiservice Media Gateway User Guide
, Issue 1
Release 9.0.0
Adding a Signaling VCC Identifier
Begin
1
On the ATM Trunking Remote IWF Configuration window, select the Go
to Sig VCC Table command.
The ATM Trunking Sig VCC Table window is displayed (see Figure 7-5).
2
Select the Add ATM Trunking Entry command.
The ATM Trunking Sig Configuration window is displayed (see
Figure 7-6).
3
Enter values in the fields on this window according to the information
provided in Table 7-10.
4
Select the Apply Configuration command.
The following message in displayed in the status line of the window:
This configuration is added.
5
To return to the ATM Trunking Sig VCC Table window to add additional
signaling VCC IDs, press Ctrl+B.
Remote IWF MAX
Call Rate
Default: 60
Range: 1–4096
Format: Numeric
(Calls per second)
Indicates the maximum number of new calls per
second within this remote IWF. This field value is
used to estimate the bandwidth resource require-
ment for an unconfigured SVC SIG VCC.
Remote IWF PCM
Encoding
Default: A-law
Range: N/A
Format: predefined
alphanumeric
Indicates the type of PCM encoding performed on
the bearer VCC.
A-law
Indicates that the traffic on the bearer VCC is
encoded as A-law traffic.
U-law
Indicates that the traffic on the bearer VCC is
encoded as U-law traffic.
None
Indicates that PCM encoding is not performed on
the bearer VCC.
[Admin Status]
Default: Up
Range: N/A
Format: predefined
alphanumeric
Specifies whether the remote IWF is active.
Up
Indicates that the remote IWF is active.
Down
Indicates that the remote IWF is inactive.
Table 7-6. Field Descriptions for the ATM Trunking Remote IWF Configuration Window (Continued)
Field Name
Field Values
Description