Using System Diagnostics
Overview of This Chapter
The PSAX system diagnostic functions give you the ability to:
•
View the status of the PSAX system including:
~
Version of the PSAX system software currently running
~
Status of the system disk on the CPUn module
~
CPUn module and memory utilization details
~
Statistics on the message pool and the cell buffers
•
Run cell test diagnostics to determine whether a specified port is operating
correctly
•
Reboot (reinitialize) the PSAX chassis, CPUn module, user-selected I/O
modules, or all components in the chassis
•
Remove configuration files
•
Unlock a telnet session remotely
•
Perform OAM loopback tests
•
Configure, activate, and deactivate OAM functions
The Diagnostics Menu window provides access to the diagnostic functions of
the PSAX system. See Table 11-1 for a description of the menu options.
Table 11-1. Menu Option Descriptions for the Diagnostics Menu Window
Menu Options
Description
System Information
Displays the System Information Screen window on which you
can view the status of the PSAX system including the version of
the PSAX system software currently running, the status of the
system disk on the CPUn module, and statistics on the message
pool and the cell buffers.
Cell Test Diagnostics
Displays the Cell Test Diagnostics window on which you can
run cell test diagnostics to determine whether a specified port is
operating correctly.
Reboot Hardware
Components
Displays the Remote Reboot Configuration window on you can
reboot (reinitialize) the PSAX chassis, the primary or backup
(standby) CPUn module, I/O and server modules, or all compo-
nents in the chassis; and perform a switchover from the primary
CPUn module to the standby CPUn module.
Note:
If you have just upgraded your PSAX system software,
make sure that all module firmware drivers are completely and
successfully downloaded before selecting this menu option.