![Lucent Technologies PacketStar PSAX 2300 User Manual Download Page 224](http://html.mh-extra.com/html/lucent-technologies/packetstar-psax-2300/packetstar-psax-2300_user-manual_1946189224.webp)
Chapter 5 Site-Specific Configuration
Configuring the Stratum 3–4 Module
5-78
255-700-447
PacketStar
®
PSAX 2300 Multiservice Media Gateway User Guide
, Issue 1
Release 9.0.0
Commands
The commands in the Stratum Configuration window are described in
Table 5-40.
Field Descriptions
The fields in the Stratum Configuration window are described in Table 5-41.
Figure 5-35. Stratum Configuration Window (LineTiming Synchronization)
Table 5-40. Commands for the Stratum Configuration Window
Command
Function
Switch Line Timing Source
Switches between the primary and secondary line timing
sources specified in the Primary Line Source and Secondary
Line Source fields. This command appears only when
LineTiming is selected in the Synchronization Source field.
Apply Stratum Configuration
Applies the values you enter in this window to the module.
Reset Stratum Display
Sets the values in this window to the last saved (applied) set
of values.
Go Back to Equipment Config-
uration
Redisplays the Equipment Configuration window.