Configuring Call Control Resource Allocation
Important
:
If you have already configured your PSAX system and you are considering changing the
sum of the values in the SPVC point-to-point calls fields, keep in mind that the sum of these values
cannot be less than the actual number of SPVC connections already configured in the PSAX system
SPVC table, which is stored in the PSAX system database.
spvcCePtToPtCalls
Default: 001000
Range: 0–10000
Format: Numeric
Specifies the maximum number of SPVC circuit emu-
lation point-to-point calls to be supported by the PSAX
system. Set the values in the SPVC point-to-point call
fields (spvcCePtToPtCalls, spvcTePtToPtCalls, spvcAt-
mPtToPtCalls, and spvcFrPtToPtCalls) so that the sum
of their values does not exceed the maximum number
of duplex calls per node for SPVCs as indicated in the
table entitled “PSAX System Performance Capabilities
Per Node.”
SPVC Priority Configurations:
If you select the value
Enabled in the spvcGlobalPriorityScheme field, the
total number of calls specified in all of the SPVC call
fields and the number of ATM trunk VCCs cannot
exceed 32 calls.
H.248 Applications:
Set the value in this field to 0.
spvcTePtToPtCalls
Default: 000100
Range: 0–10000
Format: Numeric
Specifies the maximum number of SPVC terminal
emulation point-to-point calls to be supported by the
PSAX system. Set the values in the SPVC point-to-
point call fields (spvcCePtToPtCalls, spvcTePtToPtCalls,
spvcAtmPtToPtCalls, and spvcFrPtToPtCalls) so that the
sum of their values does not exceed the maximum
number of duplex calls per node for SPVCs as indicated
in the table entitled “PSAX System Performance Capa-
bilities Per Node.”
SPVC Priority Configurations:
If you select the value
Enabled in the spvcGlobalPriorityScheme field, the
total number of calls specified in all of the SPVC call
fields and the number of ATM trunk VCCs cannot
exceed 32 calls.
H.248 Applications:
Set the value in this field to 0.
Table 5-18. Field Descriptions for the Call Control Resource Allocation Configuration Window (Continued)
Field Name
Field Values
Description