4) Flag related with operating status
(1) Sending/receiving error count for each station (total 32 stations)
- Flag name: _MRS_ERR_CNT[n] (n = 0 ~ 31)
- Data type: array byte
- Description: each station can renew number of errors.
Namely, the number of s/r errors of the station no. 1 is renewed at _MRS_ERR_CNT [0], and the number of the station no.
31, at _MRS_ERR_CNT [31].
(2) Sending/receiving error description of each station (total 32 stations)
- Flag name: _MRS_ERR[n] (n = 0 ~ 31)
- Data type: array byte
- Description:
Error code 1: time overrun error for the responding time of sending/receiving
Error code 2: NAK time error
(3) Slave PLC mode and error description of each station (total 32 stations)
- Flag name: _SRS_STATE[n] (n = 0 ~ 31)
- Data type: array byte
- Description: 0 Bit: error status of the slave PLC (1: error, 0: normal)
1-3 Bit: Reserved
4-7 Bit: operating mode of the slave PLC
4 Bit: STOP
5 Bit: RUN
6 Bit: PAUSE
7 Bit: DEBUG
(4) Status flag of the master PLC
- Flag name: _MRS_STATE [n] (n=0-31)
- Data type: array byte
- Contents:
-2 Bit: overextending M area when setting communication parameter
(5) Max/min/current sending/receiving cycle of set parameter
- Flag name:
- (Time Type) _MRS_SCAN_MAX
- (Time Type) _MRS_SCAN_MIN
- (Time Type) _MRS_SCAN_CUR
- Contents: the interval between after sending and before receiving
Summary of Contents for GLOFA G7M-DR20U
Page 28: ...Chapter 4 Names of Parts 4 3 2 G7M DRT60U N 3 G7M DT60U N 4 G7M DT60U P...
Page 29: ...Chapter 4 Names of Parts 4 4 5 G7M DR60U DC 6 G7M DRT60U N DC 7 G7M DT60U N DC...
Page 31: ...Chapter 4 Names of Parts 4 6 3 G7M DT40U N 4 G7M DT40U P 5 G7M DR40U DC...
Page 32: ...Chapter 4 Names of Parts 4 7 6 G7M DRT40U N DC 7 G7M DT40U N DC 8 G7M DT40U P DC...
Page 33: ...Chapter 4 Names of Parts 4 8 4 1 3 30 point main unit 1 G7M DR30U 2 G7M DRT30U N 3 G7M DT30U N...
Page 34: ...Chapter 4 Names of Parts 4 9 4 G7M DT30U P 5 G7M DR30U DC 6 G7M DRT30U N DC...
Page 36: ...Chapter 4 Names of Parts 4 11 2 G7M DRT20U N 3 G7M DT20U N 4 G7M DT20U P...
Page 37: ...Chapter 4 Names of Parts 4 12 5 G7M DR20U DC 6 G7M DRT20U N DC 7 G7M DT20U N DC...
Page 38: ...Chapter 4 Names of Parts 4 13 8 G7M DT20U P DC...
Page 159: ...Chapter 7 Usage of Various Functions 7 52 c Program...
Page 183: ...Chapter 7 Usage of Various Functions 7 76 c Program...
Page 253: ...Chapter 8 Communication Functions 8 27 b When uses Ch 1 Built in RS 485...
Page 356: ...Appendix 1 System Definitions App1 9 6 Position Parameter...
Page 357: ...Appendix 1 System Definitions App1 10 7 High Speed Counter Parameter...