Chapter 1. General
1-
2
1.2 Feature
1) GLOFA-GM7U series have the following features.
1) GLOFA-GM series features
(1) Designed on the basis of international standard specifications (IEC61131-3)
y
Supports easy programming
y
Provides IEC61131-3 Language (IL / LD / SFC)
(2) Supports an open network by the international standard communication protocol
(3) High speed processing with an embedded operation-dedicated processor.
(4) Various special modules that enlarge the PLC application range
2) GM7U series are extremely compact to fit a wide range of applications.
(1) High speed processing
High speed processing with 0.1~0.9
μ
s/step
(2) Various built-in functions
Only with the base unit, the user can configure various systems because it has many built-in functions.
•
Fast Processing Applications
-Pulse catch: allows the base unit to read a pulse stably as short as 10
μ
s
-High-speed counter: supports high-speed counting up to 1 phase 100kHz, and 2 phase 50kHz
-External contact interrupts: enables the applications which require immediate responses by using a built-in 8-point
interrupt input
•
The input filter function helps to reduce the possibility of false input conditions from external noise, such as signal
chattering. The filter time can be programmed from 0 to 1000 ms.
•
The built-in positioning control function enables to control a stepping motor or a servo motor without a separate
positioning module. (DRT, DT type)
•
Using RS-232C and RS-485 built-in ports, GM7U can connect to external devices, such as computers or
monitoring devices. These devices can communicate 1:1 with the GM7U or GM6 system.
•
Using the built-in PID control function, the PID control system can be configured easily without using separate
PID module.
(3) The user can easily turn On/Off the system with RUN/STOP switch.
(4) The user can configure various systems using a separate Cnet I/F module.
(5) The user program can be easily saved in EEPROM by simple manipulation in GMWIN without using external memory.
(6) Advanced self-diagnostic functions
- GLOFA-GM7U series can detect the errors precisely with more detailed error codes.
(7) Unintentional reading and writing can be prevented by using a password.
(8) Restart mode setting
- The user can select Cold/Warm restart mode.
Summary of Contents for GLOFA G7M-DR20U
Page 28: ...Chapter 4 Names of Parts 4 3 2 G7M DRT60U N 3 G7M DT60U N 4 G7M DT60U P...
Page 29: ...Chapter 4 Names of Parts 4 4 5 G7M DR60U DC 6 G7M DRT60U N DC 7 G7M DT60U N DC...
Page 31: ...Chapter 4 Names of Parts 4 6 3 G7M DT40U N 4 G7M DT40U P 5 G7M DR40U DC...
Page 32: ...Chapter 4 Names of Parts 4 7 6 G7M DRT40U N DC 7 G7M DT40U N DC 8 G7M DT40U P DC...
Page 33: ...Chapter 4 Names of Parts 4 8 4 1 3 30 point main unit 1 G7M DR30U 2 G7M DRT30U N 3 G7M DT30U N...
Page 34: ...Chapter 4 Names of Parts 4 9 4 G7M DT30U P 5 G7M DR30U DC 6 G7M DRT30U N DC...
Page 36: ...Chapter 4 Names of Parts 4 11 2 G7M DRT20U N 3 G7M DT20U N 4 G7M DT20U P...
Page 37: ...Chapter 4 Names of Parts 4 12 5 G7M DR20U DC 6 G7M DRT20U N DC 7 G7M DT20U N DC...
Page 38: ...Chapter 4 Names of Parts 4 13 8 G7M DT20U P DC...
Page 159: ...Chapter 7 Usage of Various Functions 7 52 c Program...
Page 183: ...Chapter 7 Usage of Various Functions 7 76 c Program...
Page 253: ...Chapter 8 Communication Functions 8 27 b When uses Ch 1 Built in RS 485...
Page 356: ...Appendix 1 System Definitions App1 9 6 Position Parameter...
Page 357: ...Appendix 1 System Definitions App1 10 7 High Speed Counter Parameter...