Commissioning and configuration
138
BCL 548
i
Leuze electronic
Parameter length
8 bytes
Input data
None
Output data
None
Reading reliability
Min. reading reliability to be
achieved in order to output a
read code.
6
UNSIGNED8
1 … 100
4
-
Check digit proce-
dure
Used check digit procedure 7.0 … 7.6
BitArea
0: Standard check digit
evaluation
1: No check digit verifi-
cation
2: MOD10 Weight 3
3: MOD10 Weight 2
4: MOD10 Weight 4_9
5: MOD11 Cont
6: MOD43
7: MOD16
0
-
Check digit output
Turns the check digit output
on or off. Standard means
that the check digit is trans-
mitted according to the
applicable standard for the
selected code type.
If
no check digit transmis-
sion is intended
for the
selected code type, then
"
Standard
" means that the
check digit is
not
transmit-
ted and "
Not Standard
"
means that the check digit is
transmitted anyway.
7.7
Bit
Check digit output
0: Standard
1: Not standard
0
-
1)
Cf. in section 10.5.2 Permanently defined parameters / device parameters the notice on
number of digits.
Parameter
Description
Rel. addr.
Data type
Value range
Default
Unit
Table 10.4:
Parameters for modules 1-4 (cont.)