Commissioning and configuration
162
BCL 548
i
Leuze electronic
10.10.2 Module 51 – Data filtering
PROFINET-IO module identifier
Module-ID 1051
Submodule-ID 1
Description
Configuration of the data filter.
Parameter
Parameter length
60 byte
Input data
None
Output data
None
Filter string
The filter string is used to define passthrough filters for bar codes.
An arbitrary number of '?' are permitted as placeholders for an arbitrary character at exactly
this position. Also permitted are '*' as placeholders for a character sequence of arbitrary
length, and an 'x' if the character at the respective position is to be deleted.
Notice!
ASCII characters that cannot be displayed (<0x20h) must not be used.
Parameter
Description
Addr. Data type
Value range
Default
Unit
Bar code filter string 1 Filter expression 1
0
STRING
30 characters null
terminated
1 … 30 bytes of ASCII characters *
-
Bar code filter string 2 Filter expression 2
30
STRING
30 characters null
terminated
1 … 30 bytes of ASCII characters \00
-
Table 10.30:
Parameters for module 51