Online commands
222
BCL 548
i
Leuze electronic
Parameter
PT<BCC type><PS type><Status><Adr.><P.value adr.>
<P.value adr+1>…[;<Adr.><P.value adr.>][<BCC>]
<BCC type>
Check-digit function during transfer,
unit [dimensionless]
’0’
No check digit
’3’
BCC mode 3
<PS type>
Memory from which the values are to be read,
unit [dimensionless]
’0’
Parameter values stored in the flash memory
’3’
Operating values stored in RAM
<Status>
Mode of parameter processing, without function here, unit [dimen-
sionless]
’0’
No reset after parameter change, no further parameters
’1’
No reset after parameter change, additional parameters follow
’2’
With reset after parameter change, no further parameters
’6’
Set parameters to factory setting, no further parameters
’7’
Set parameters to factory settings, lock all code types; the code-
type setting must follow in the command!
<Adr.>
Relative address of the data within the data set,
’aaaa’
Four-digit, unit [dimensionless]
<P.value>
Parameter value of the -bb- parameter stored at this address. The
parameter set data is converted from HEX format to a 2-byte-ASCII
format for transfer.
<BCC>
Check sum calculated as specified under BCC type
Acknowledgment
’PS=<aa>’
Parameter reply:
<aa>
Status acknowledgement, unit [dimensionless]
’01’
Syntax error
’02’
Impermissible command length
’03’
Impermissible value for checksum type
’04’
Invalid check sum received
’05’
Impermissible data length
’06’
Invalid data (parameter limits violated)
’07’
Invalid start address
’08’
Invalid parameter set
’09’
Invalid parameter set type
Command
’PT’