Commissioning and configuration
174
BCL 548
i
Leuze electronic
10.12.4 Module 63 – Alignment
PROFINET-IO module identifier
Module-ID 1063
Submodule-ID 1
Description
The module defines input and output data for the alignment mode of the BCL 504
i
. The align-
ment mode is used for easy alignment of the BCL 504
i
with the bar code. Using the trans-
mitted decoding quality as a percentage, the optimum alignment can be easily selected.
This module should not be used in connection with module 81 (AutoReflAct) as this may
cause malfunctions.
Parameter
None
Input data
Input data length
1 byte
Output data
Output data length
1 byte
Input data
Description
Addr.
Data type
Value range
Init value Unit
Decoding quality
Transmits the current decoding quality of the
bar code located in the scanning beam
0
Byte
0 … 100
0
Percent-
age
Table 10.39:
Input data for module 63
Output data
Description
Addr.
Data type
Value range
Init value Unit
Alignment mode
Signal activates and deactivates the
alignment mode for optimum align-
ment of the BCL 504
i
with the bar code
0.0
Bit
0 -> 1: On
1 -> 0: Off
0
-
Table 10.40:
Output data for module 63