Online commands
Leuze electronic
BCL 548
i
215
TNT
35/7-2
4
V
Set the state of the switching outputs
Deactivate switching output
Command
’OA’
Description
This command is used to set the states of the switching inputs/outputs that are con-
figured as a switching output. The logic state is specified, i.e., an inverted logic is taken
into account (e.g., inverted logic and a state of High corresponds to a voltage of 0V at
the switching output).
The values of the switching inputs/outputs that are not configured as
switching outputs are ignored. You may also use only a selection of the
existing switching inputs/outputs as long as these are listed in ascend-
ing order.
Parameter
’OA [S1=<a>][;S2=<a>][;S3=<a>][;S4=<a>]’
<a>
State of the switching output
’0’
Low
’1’
High
Acknowledgment
’OA=<aa>’
<aa>
Status acknowledgement, unit [dimensionless]
’00’
OK
’01’
Syntax
error
’02’
Parameter
error
’03’
Other
error
Command
’OD’
Description
The switching outputs 1 - 4 can be deactivated with this command. The respective
port must have been configured as a switching output. The logic state is output, i.e.,
an inverted logic is taken into account (e.g., inverted logic and a state of High corre-
sponds to a voltage of 0V at the switching output).
Parameter
’OD<a>’
<a>
Selected switching output [1..4], unit [dimensionless]
Acknowledgment
None