Commissioning and configuration
Leuze electronic
BCL 548
i
179
TNT
35/7-2
4
V
Switch-on time ton
This parameter specifies the min. activation duration for the selected input function in ms.
The actual activation duration is calculated from the switch-on time as well as the switch-
off delay.
Figure 10.8: Switch-on time in input mode
Switch-off delay td_off
This parameter specifies the duration of the switch-off delay in ms.
Figure 10.9: Switch-off delay in input mode
Input signal
Output signal
Start-up delay td_on
Switch-on time
ton
Switch-off delay td_off
Input signal
Output signal
Start-up delay td_on
Switch-on time ton
Switch-off delay td_off