Fast commissioning / operating principle
Leuze electronic
BCL 548
i
23
TNT
35/7-2
4
V
3.6
Further settings
Carry out further settings via the PROFINET-IO Controller, such as the control of the
decoding and processing of the read data and the configuration of the connected switching
inputs and outputs, using the parameters provided by the GSD file.
Activate the desired modules (at least module 10 and one of the modules 21 … 27).
A detailed description of the modules can be found beginning on chapter 10.6.
3.7
Bar code reading
With the aid of the "Action menu", you can instruct the BCL 548
i
to read a bar code.
To test, you can use the following bar code in the 2/5 Interleaved format. The bar code
module here is 0.5:
The read information appears in the display and is simultaneously passed on to the superior
system (PLC or PC).
Please check the incoming data of the bar code information there.
Alternatively, you can connect a photoelectric sensor or a 24 V DC switching signal to the
SW IN/OUT socket for read activation. To do this, however, you must appropriately
configure the switching input (see chapter 7.2.3 "SW IN/OUT – Switching input/switching
output").
Actions
o Start decoding
o Start alignment
o Start auto-setup
o Start teach-in
In the main menu, use the
buttons to select the
Actions
menu
item. Activate the Actions menu with
. Then select
Start decod-
ing
with
and press
again to start the bar code reading oper-
ation.
Modul 0,5
6677889900