Commissioning and configuration
198
BCL 548
i
Leuze electronic
10.16 Special Functions
10.16.1 Module 90 – Status and control
PROFINET-IO module identifier
Module-ID 1090
Submodule-ID 1
This module supplies various BCL 548
i
status information to the PROFINET-IO master.
Various functions of the BCL 548
i
can be controlled via the master's output data.
Parameter
None
Input data
Input data length
1 byte
Output data
None
Input data
Description
Addr.
Data type
Value range
Init value Unit
Reserved
Free
0.0
Bit
0
-
AutoRefl state
Signal state of the AutoRefl module
0.1
Bit
0: Reflector is recog-
nized
1: Reflector is hid-
den
1
-
Auto Control result
Indicates whether the result of the
AutoControl function was a good or
bad reading.
0.2
Bit
0: Quality good
1: Quality bad
0
-
Reserved
Free
0.3
Bit
0
-
RefCode comparison
state 1
The signal indicates whether the
decoded bar code corresponds to the
reference code with regard to the
comparison criteria as defined in the
comparison function 1. If it matches,
the value 1 is output.
0.4
…
0.5
Bit
0: Not equal
1: Equal
2: Unknown
2
-
RefCode comparison
state 2
The signal indicates whether the
decoded bar code corresponds to the
reference code with regard to the
comparison criteria as defined in the
comparison function 2. If it matches,
the value 1 is output.
0.6
…
0.7
Bit
0: Not equal
1: Equal
2: Unknown
2
-
Table 10.56:
Input data for module 90 – Status and control