Commissioning and configuration
Leuze electronic
BCL 548
i
137
TNT
35/7-2
4
V
10.7
Decoder modules
10.7.1
Modules 1-4 – Code table extensions 1 to 4
PROFINET-IO module identifier
Module-ID 1001…1004
Submodule-ID 1
Description
The modules extend the code type tables of the device parameters and permit the additional
definition of further 4 code types together with the respective number of digits.
Parameter
Parameter
Description
Rel. addr.
Data type
Value range
Default
Unit
Code type
Released code type; no code
means that all subsequent
code tables are also deacti-
vated.
The valid number of digits
also depends on the code
type.
0.0 … 0.5
BitArea
0: No code
1: 2/5
Interleaved
2: Code39
3: Code32
6: UPC,
UPCE
7: EAN8,
EAN13
8: Code128
10: EAN Addendum
11: Codabar
12: Code93
13: GS1 DataBar
Omnidirectional
14: GS1 DataBar Limited
15: GS1 DataBar
Expanded
0 -
Number-of-digits
mode
Interpretation of the number
of digits
1.6
Bit
0: Enumeration
1: Range
0
-
Digits 1
1)
Decodable number of digits;
in the case of a range, this
number defines the lower
limit.
1.0 … 1.5
UNSIGNED8
0 … 63
0
-
Digits 2
Decodable number of digits;
in the case of a range, this
number defines the upper
limit.
2
UNSIGNED8
0 … 63
0
-
Digits 3
Decodable number of digits
in the enumeration mode.
3
UNSIGNED8
0 … 63
0
-
Digits 4
Decodable number of digits
in the enumeration mode.
4
UNSIGNED8
0 … 63
0
-
Digits 5
Decodable number of digits
in the enumeration mode.
5
UNSIGNED8
0 … 63
0
-
Table 10.4:
Parameters for modules 1-4