10.12.6 Module 65 – Deflection mirrors
PROFINET-IO module identifier
Module-ID 1065
Submodule-ID 1
Description
Module for supporting the deflection mirror.
Parameter
Parameter length
2 bytes
Input data
None
Output data
None
10.13 Switching inputs/ outputs SWIO 1 … 4
These modules define the mode of operation of the 4 digital switching inputs and outputs
(I/Os). They are separated into individual modules for configuring the individual I/Os and a
shared module for signaling the status and controlling all I/Os.
10.13.1 Parameters for operating as an output
Start-up delay
With this setting, the output pulse can be delayed by the specified time (in ms).
Switch-on time
Defines the switch-on time period for the switching input. Any activated switch-off function
then no longer has any function.
A value of 0 causes the output to be set statically; this means that the selected input func-
tion(s) activate the output, and the selected switch-off function(s) deactivate it again.
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Deflection angle
Lateral beam exit in degrees relative to
the zero position
0 …1
SIGNED16
-100 … +100
0
1/10°
Table 10.42: