Display and control panel
108
BCL 548
i
Leuze electronic
Notice!
If a password was set, parameter enabling cannot be accessed until this password has been
entered, see "Password for parameter enabling" on page 109.
Attention!
The BCL 548
i
is deactivated on the PROFINET-IO if parameter enabling is activated via the
display. The device is reactivated on the PROFINET-IO after parameter enabling is exited.
Notice!
In the PROFINET-IO network, configuration is performed exclusively via the
PROFINET-IO Controller.
Parameters set via the display when operating the BCL 548
i
on the PROFINET-IO are over-
written by the parameters set in the GSD modules. For GSD modules which are not actively
used on the PROFINET-IO, the default settings of the bar code reader apply, see "Overview
of the project modules" on page 134.. Thus, the PROFINET-IO presets values to all param-
eters.
Attention!
If parameters are changed via the display during bus operation, the BCL 548
i
is separated
from the PROFINET-IO at the moment parameter enabling is activated via the display.
Parameters set by the PROFINET-IO are moved to the background, and changes to param-
eters can be made via the display. When parameter enabling is exited, the BCL 548
i
is auto-
matically reconnected to the PROFINET-IO. Upon connection to the PROFINET-IO, the
BCL 548
i
receives all parameters from the PROFINET-IO Controller.
Changes made via the display are overwritten!
Device settings for operating the BCL 548
i
on the PROFINET-IO are managed and con-
figured exclusively by the PROFINET-IO Controller.
Press the enter button to switch on parameter enabling.
Parameter enabling
OFF
O ON
Standard ----- Unit
OFF | |
The PWR LED lights up red. You can now set individual parameters via
the display.
Press the ESC button twice to return to the main menu.
ESC
ESC