Display and control panel
Leuze electronic
BCL 548
i
99
TNT
35/7-2
4
V
Digital SWIO
The
Digital SWIO
submenu is used to configure the 4 switching inputs/outputs of the
BCL 548
i
.
Table 8.3:
Digital SWIO submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
Sw. input/
output 1
I/O mode
Input / Output / Passive
Determines the function of switching
input/output 1.
In the case of passive, the connection is
on 0V if the
Inverted
parameter is set
to
OFF
,
and on +UB if the
Inverted
parameter is set to
ON
.
Input
Switching input
Inverted
OFF / ON
OFF
= activation of the switching input
function upon high level at the switching
input
ON
= activation of the switching input
function upon low level at the switching
input
OFF
Debounce time
Value from 0 to 1000
Time in milliseconds for which the input
signal must be present and stable.
5
Start-up delay
Value from 0 to 65535
Time in milliseconds between the end of
the debounce time and activation of the
function configured below.
0
Pulse duration
Value from 0 to 65535
Minimum activation time in milliseconds
for the function configured below.
0
Switch-off delay
Value from 0 to 65535
Time in milliseconds for which the func-
tion configured below remains activated
after the switching input signal is deac-
tivated and the pulse duration has
expired.
0
Function
No BCL500i function
Reading gate start/stop
Rd. gate stop
Rd. gate start
Teach reference code
Autoconfig start/stop
The function set here is carried out after
the switching input is activated.
Reading gate
start/stop