Fast commissioning / operating principle
Leuze electronic
BCL 548
i
19
TNT
35/7-2
4
V
3.4
Starting the device
Connect the supply v10 … 30VDC (typ. +24VDC); the BCL 548
i
starts up and
the bar code reading window appears on the display:
First, you need to assign its individual device name to the BCL 548
i
. The PLC must commu-
nicate this device name to the participant during the "device naming". Further information
may be found below and in chapter "Step 5 – Configuration of the device name - naming
the device" on page 121.
3.5
Commissioning the BCL 548i on the PROFINET-IO
Complete the necessary steps for commissioning a Siemens-S7 control as described
below.
Further information regarding the individual commissioning steps is provided in see chapter
10.4 "Configuration steps for a Siemens Simatic S7 control".
3.5.1
Preparing the control system
In the first step, assign an IP address to the IO Controller (S7 PLC) and prepare the control
for a consistent data transmission.
Notice!
If an S7 control is used, you need to ensure that Simatic-Manager Version 5.4 + service
pack 5 (V5.4+SP5) or higher is used.
3.5.2
Installing the GSD file
For the subsequent configuration of the IO devices, e.g., BCL 548
i
, the corresponding GSD
file must be loaded first. All data in modules required for operating the BCL 548
i
is described
in this file. These are input and output data and device parameters for the functioning of the
BCL 548
i
and the definition of the control and status bits.
Install the GSD file associated with the BCL 548
i
in the PROFINET-IO Manager of your
control.
By default, parameter enabling is deactivated and you cannot change
any settings. If you wish to carry out the configuration via the display,
you must activate parameter enabling. Further information can be found
in chapter "Parameter enabling" on page 107.
LNK0
LNK1