Display and control panel
Leuze electronic
BCL 548
i
107
TNT
35/7-2
4
V
Start teach-in
The teach-in function can be used to conveniently read reference code 1.
Use the
button to activate the teach-in function and place a bar code which contains
the content that you wish to store as the reference code in the reading beam of the
BCL 548
i
.
The following display appears:
The following information is displayed:
RC13
means that reference code number 1 is stored in RAM. This is always output.
xx
defined code type (see auto-setup)
z
defined code information (1 … 63 characters)
8.4
Operation
Shown here is an example describing important operating procedures in detail.
Parameter enabling
During normal operation parameters can only be viewed. If parameters need to be changed,
the
ON
menu item in the
Parameter enabling
menu must be activated. To do this proceed
as follows:
Actions
o Stop teach-in
RC13xxzzzzzz
Parameter 1
Parameter handling
Decoder table
Digital SWIO
ETHERNET
In the parameter menu, use the
buttons to select the
Parameter handling
menu item.
Press the enter button to enter the
Parameter handling
menu.
Parameter handling 1.1
o Parameter enabling
Parameters to default
In the Parameter handling menu, use the
buttons to select the
Parameter enabling
menu item.
Press the enter button to enter the
Parameter enabling
menu.
Parameter enabling
OFF
o ON
Standard ----- Unit
OFF | |
In the Parameter enabling menu, use the
buttons to select the
ON
menu item.