10.13.5 Module 70 – Switching input/output SWIO1
PROFINET-IO module identifier
Module-ID 1070
Submodule-ID 1
Parameter
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Function
This parameter defines whether
I/O 1 functions as an input or as an
output.
0.0
Bit
0: Input
1: Output
0
-
Mode of operation for configuration as an output
DC bias level
The parameter defines the DC bias
level of the switching output and,
thus, simultaneously whether the
output is low-active (0) or high-
active (1).
0.1
Bit
0: LOW (0V)
1: HIGH (+Ub)
0
-
Reserved
Free
0.2 … 0.7
Start-up delay
With this parameter, the output
pulse may be delayed by a set time
period.
1
UNSIGNED16
0 … 65535
0
ms
Switch-on time
The parameter defines the switch-
on time period for the switching
output. If the value is 0, the signal
is static.
3
UNSIGNED16
0 … 1300
400
ms
Switch-on
function 1
This parameter specifies an event
which can set the switching out-
put.
5
UNSIGNED8
switch-off
functions" on
page 180
0
-
Switch-on
function 2
This parameter specifies an event
which can set the switching out-
put.
Switch-on function 1 and switch-
on function 2 are OR linked.
6
UNSIGNED8
switch-off
functions" on
page 180
0
-
Switch-off
function 1
This parameter specifies an event
which can reset the switching out-
put.
7
UNSIGNED8
switch-off
functions" on
page 180
0
-
Switch-off
function 2
This parameter specifies an event
which can reset the switching out-
put.
Switch-off function 1 and switch-
off function 2 are OR linked.
8
UNSIGNED8
switch-off
functions" on
page 180
0
-
Comparative
value
(Event Counter)
If the number of activation events
of the selected switch-on function
reaches this comparative value,
the switching output is activated. A
deactivation event of the selected
switch-off function resets the
counter.
9
UNSIGNED16
0..65535
0
-
Compare mode
(Event Counter)
Specifies whether the switching
output switches only on parity
(once) or also in the event of
greater or equal to (multiple times)
after the comparative value is
reached.
11
UNSIGNED8
0: SWOUT
switches
once
1: SWOUT
switches sev-
eral times
0
-
Table 10.45:
Parameters for module 70 – Input/Output 1