Commissioning and configuration
Leuze electronic
BCL 548
i
195
TNT
35/7-2
4
V
Parameter length
8 byte
Input data
None
Output data
None
Bar code compar-
ison mode
This parameter specifies
which decoded bar codes
are to be used for the ref-
erence bar code compar-
ison.
6
UNSIGNED8
0: Only the first bar code is used for
the comparison.
1: Only the second bar code is used
for the comparison.
2: All bar codes are used for the com-
parison. All comparisons must be
successful.
3: All bar codes are used for the com-
parison. One comparison must be
successful.
3
-
Reference code
completeness
comparison
If this parameter is set,
the basic condition for a
positive reference code
comparison is that all
mandatory bar codes that
are to be read within a
reading gate were actu-
ally read. If this condition
is not satisfied, no posi-
tive reference code com-
parison is achieved.
7.0
Bit
0: Completeness comparison
switched off.
1: Completeness comparison
switched on.
0
-
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Table 10.53:
Parameters for module 82 – Reference code comparison (cont.)