Commissioning and configuration
Leuze electronic
BCL 548
i
157
TNT
35/7-2
4
V
10.9.11 Module 38 – Code direction
PROFINET-IO module identifier
Module-ID 1038
Submodule-ID 1
Description
The module defines input data for the communication of the detected code direction of the
currently transmitted bar code.
Parameter
None
Input data
Input data length
1 byte
Output data
None
Comment:
A decoding result of type "No Read" has as code direction the value 2 = unknown!
10.9.12 Module 39 – Number of digits
PROFINET-IO module identifier
Module-ID 1039
Submodule-ID 1
Description
The module defines input data for the communication of the number of digits of the currently
transmitted bar code.
Parameter
None
Input data
Input data length
1 byte
Output data
None
Input data
Description
Addr.
Data type
Value range
Init value Unit
Code direction
Code direction of the transmitted bar
code
0
UNSIGNED8
0: Normal
1: Inverted
2: Unknown
0
-
Table 10.25:
Input data for module 38
Input data
Description
Addr.
Data type
Value range
Init value Unit
Number of digits
Number of digits of the transmitted bar
code
0
UNSIGNED8
0 … 48
0
-
Table 10.26:
Input data for module 39