![Leuze electronic BCL548i Manual Download Page 195](http://html.mh-extra.com/html/leuze-electronic/bcl548i/bcl548i_manual_1883924195.webp)
Commissioning and configuration
Leuze electronic
BCL 548
i
193
TNT
35/7-2
4
V
Parameter length
8 byte
Input data
None
Output data
None
Reference code
comparison mode
This parameter deter-
mines how and which ref-
erence bar codes (RC) are
to be used for the bar code
comparison.
5
UNSIGNED8
0: Only the first RC is used for the
comparison.
1: Only the second RC is used for the
comparison.
2: RC 1 and 2 are used for the com-
parison. Both conditions for RC 1
and 2 must be satisfied for a posi-
tive comparison.
3: RC 1 and 2 are used for the com-
parison. One of the two conditions
for reference bar codes 1 and 2
must be satisfied.
0
-
Bar code compar-
ison mode
This parameter specifies
which decoded bar codes
are to be used for the ref-
erence bar code compar-
ison.
6
UNSIGNED8
0: Only the first bar code is used for
the comparison.
1: Only the second bar code is used
for the comparison.
2: All bar codes are used for the com-
parison. All comparisons must be
successful.
3: All bar codes are used for the com-
parison. One comparison must be
successful.
3
-
Reference code
completeness
comparison
If this parameter is set,
the basic condition for a
positive reference code
comparison is that all
mandatory bar codes that
are to be read within a
reading gate were actu-
ally read. If this condition
is not satisfied, no posi-
tive reference code com-
parison is achieved.
7.0
Bit
0: Completeness comparison
switched off.
1: Completeness comparison
switched on.
0
-
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Table 10.52:
Parameters for module 81 – Reference code comparison (cont.)