![Leuze electronic BCL548i Manual Download Page 198](http://html.mh-extra.com/html/leuze-electronic/bcl548i/bcl548i_manual_1883924198.webp)
Commissioning and configuration
196
BCL 548
i
Leuze electronic
10.15.3 Module 83 – Reference code comparison pattern 1
PROFINET-IO module identifier
Module-ID 1083
Submodule-ID 1
Description
This module can be used to define the 1st comparison pattern
Parameter
Parameter length
31 byte
Input data
None
Output data
None
Notice!
The defined comparison pattern affects both reference code comparators (Module 81 –
Reference code comparator 1 and Module 82 – Reference code comparator 2).
ASCII characters that cannot be displayed (<0x20h) must not be used in the comparison
pattern.
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Code type com-
parison pattern 1
Specifies the type of the reference bar
code.
0
UNSIGNED8
0: No code
1: 2/5
Interleaved
2: Code39
3: Code32
6: UPC,
UPCE
7: EAN8,
EAN13
8: Code128
10: EAN Addendum
11: Codabar
12: Code93
13: GS1 DataBar Omni-
directional
14: GS1 DataBar Lim-
ited
15: GS1 DataBar Omni-
directional
Expanded
0
-
Comparison pat-
tern 1
Parameter string describing the content
of the reference bar code. Note: You can
also use the two placeholder characters
that are stored in the "Wildcard charac-
ter" and "Don't care character" parame-
ters. If the string is empty, no comparison
takes place. If the most recently stored
character is the wildcard character, the
comparison is only carried out up to the
character before this wildcard character.
In this way it is possible to switch off a
comparison according to bar code length.
1
STRING
30 characters
null termi-
nated
1 … 30 bytes of ASCII
characters
\00
-
Table 10.54:
Parameter module 83 – Reference code comparison pattern