Commissioning and configuration
Leuze electronic
BCL 548
i
161
TNT
35/7-2
4
V
Parameter length
8 byte
Input data
None
Output data
None
All comparison criteria are AND linked; this means all active comparisons must be fulfilled
before the just-decoded bar code can be identified as already decoded and then deleted.
Comparison param-
eter - oscillating
mirror position
If this parameter is not
equal to 0, the bar code
position in the swivel
range of the oscillating
mirror is used to deter-
mine whether identical
bar codes have already
been decoded. A +/-
bandwidth in degrees
must then be specified,
within which the same
bar code is permitted to
be in the oscillating
mirror swivel range.
4 … 5 UNSIGNED16
0 … 200
0
1/10
degree
Comparison param-
eter - scanning time
info
If this parameter is not
equal to 0, the decod-
ing time (time at which
the bar code was
decoded) is used to
determine whether
identical bar codes
have already been
detected. Here, a dif-
ference time specified
in milliseconds ensures
that identical bar codes
may only occur within
this time.
6 … 7 UNSIGNED16
0 … 65535
0
ms
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Table 10.29:
Parameters for module 50 (cont.)