Commissioning and configuration
130
BCL 548
i
Leuze electronic
10.5.2
Permanently defined parameters / device parameters
On the PROFINET-IO, parameters may be stored in modules or may be defined permanently
in a PROFINET-IO participant.
The permanently defined parameters are called "common" parameters or device-specific
parameters, depending on the configuration tool.
These parameters must always be present. They are defined outside configuration modules
and are thus connected to the base module (
DAP
:
D
evice
A
ccess
P
oint that is addressed
via slot 0/subslot 0
In Simatic Manager, the permanently defined parameters are set via object properties of
the device. The module parameters are set via the module list of the selected device. By
selecting the project properties of a module, the respective parameters may be set if
required.
The following list contains the device parameters that are permanently defined in the
BCL 548
i
(DAP Slot 0/Subslot 0) but are configurable. These parameters always exist and
are available independent of the modules.
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Profile num-
ber
Number of the activated profile. For BCL 548
i
: constant
with value 0
0
UNSIGNED8
0 … 255
0
-
Code type 1
Released code type; no code means that all subsequent
code tables are also deactivated.
The valid number of digits also depends on the code type.
1.0 …
1.5
BitArea
0: No code
1: 2/5
Interleaved
2: Code39
3: Code32
6: UPC,
UPCE
7: EAN8,
EAN13
8: Code128
10: EAN Addendum
11: Codabar
12: Code93
13: GS1 DataBar
Omnidirectional
14: GS1 DataBar
Limited
15: GS1 DataBar
Expanded
1 -
Number-of-
digits mode
Specifies how the subsequent numbers of digits are to be
interpreted.
2.6
Bit
0: Enumeration
1: Range
0
-
Digits 1
Decodable number of digits; in the case of a range, this
number defines the lower limit.
1)
2.0 …
2.5
UNSIGNED8
0 … 63
10
-
Digits 2
Decodable number of digits; in the case of a range, this
number defines the upper limit.
3
UNSIGNED8
0 … 63
0
-
Digits 3
Decodable number of digits in the
enumeration
mode.
4
UNSIGNED8
0 … 63
0
-
Digits 4
Decodable number of digits in the
enumeration
mode.
5
UNSIGNED8
0 … 63
0
-
Digits 5
Decodable number of digits in the
enumeration
mode.
6
UNSIGNED8
0 … 63
0
-
Reading
reliability
Min. reading reliability to be achieved in order to output a
read code.
7
UNSIGNED8
1 … 100
4
-
Table 10.2:
Device parameters