Function library
Code table
9-260
l
EDSVS9332S-D12 EN 3.0
Code
Important
Possible settings
No.
Selection
Lenze
LCD
C0122 OH4 LIMIT
85
45
{1 °C}
85
Temperature for OH4
Warning threshold - heatsink temperature
C0125 BAUD RATE
0
0
1
2
3
4
9600 baud
4800 baud
2400 baud
1200 baud
19200 baud
LECOM baud rate
LECOM baud rate for 2102 module
C0126 MONIT CE0
3
0
2
3
TRIP
Warning
Off
Conf. CE0
Configuration of communication error
monitoring with automation interface CE0
C0130 ACT TI
NSET act. Ti times
active T
i
times of NSET
C0134 RFG CHARAC
0
0
1
linear
S-shaped
NSET RFG characteristic
Ramp characteristic for main setpoint
C0135 CONTROL WORD
0
0
{1}
65535
Control word
Controller control word for LECOM-A/B/LI or
operating module.
C0136
1 CTRLWORD C135
Control word C135
2 CTRLWORD CAN
Control word CAN
3 CTRLWORD AIF
Control word AIF
C0141 FCODE (SETPOINT)
0.0
-199.9
{0.1 }
199.9
Main setpoint
C0142 START OPTIONS
1
0
1
Start lock
Auto start
Start option
Start conditions are executed:
after mains connection
after message (t > 0.5s)
after TRIP
C0150 STATUS WORD
0
{1}
65535
Status word
when networked with automation
interfaces
Binary interpretation indicates the bit states
C0151 FDO (DW)
Display (hex.) of the free digital output signals
configured with C0116
Binary interpretation indicates the bit states
C0155 STATUS WORD 2
Bit00
Fail
Bit08
R/L
Status word 2
Bit01
Mmax
Bit09
–
Extended decimal status word
Binar interpretation indicates the bit states
Bit02
Imax
Bit10
–
Binary interpretation indicates the bit states
Bit03
IMP
Bit11
–
Bit04
RDY
Bit12
–
Bit05
CINH
Bit13
–
Bit06
TRIP
Bit14
–
Bit07
Init
Bit15
–
[C0156]
→
Selection list 2 Configuration of the free bits of the status word
1 STAT.B0
2000
DCTRL-PAR*1-O
g
2 STAT.B2
5002
MCTRL-IMAX
3 STAT.B3
5003
MCTRL-MMAX
4 STAT.B4
5050
NSET-RFG I=O
5 STAT.B5
10650 CMP1-OUT
6 STAT.B14
505
DCTRL-CW/CCW
7 STAT.B15
500
DCTRL-RDY
C0157 (C0156)
0
1
C0161 ACT TRIP
All fault indications
Error message TRIP
Momentary fault indication (as under C0168/1)
C0167 RESET FAILMEM
0
0
1
No reset
Reset
History buffer reset
Clears the history buffer
Summary of Contents for EVS 9300 series
Page 1: ...L System Manual EDSVS9332S 31S Global Drive 9300 servo inverter 31S...
Page 28: ...Contents ii L EDSVS9332S B EN 3 0...
Page 38: ...Technical data 3 6 Dimensions 3 10 L EDSVS9332S B EN 3 0...
Page 90: ...Contents ii L EDSVS9332S C EN 3 0...
Page 108: ...During operation Operating notes 6 6 l EDSVS9332S C EN 3 0...
Page 114: ...Contents iv L EDSVS9332S D11 EN 3 0...
Page 378: ...Contents ii L EDSVS9332S D12 EN 3 0...
Page 452: ...Contents ii L EDSVS9332S E EN 3 0...
Page 466: ...Contents ii L EDSVS9332S K EN 3 0...
Page 467: ...Selection help 11 1 l EDSVS9332S K EN 3 0 Part K 11 Selection help 11 1 See folder Planning...
Page 468: ...Selection help 11 2 l EDSVS9332S K EN 3 0...
Page 485: ...Contents i L EDSVS9332S L EN 3 0 13 Signal flow diagrams 13 1...
Page 486: ...Contents ii L EDSVS9332S L EN 3 0...
Page 488: ...Signal flow charts 13 2 L EDSVS9332S L EN 3 0...
Page 491: ...Contents i L EDSVS9332S M EN 3 0 14 Glossary 14 1 14 1 Index 14 3...
Page 492: ...Contents ii L EDSVS9332S M EN 3 0...