Function library
Function blocks
9.2.24
Control of the drive controller (DCTRL)
9-93
L
EDSVS9332S-D11 EN 3.0
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
DCTRL-CINH1
d
C0878/1
bin
C0870/1
2
1000
HIGH = inhibit controller
DCTRL-CINH2
d
C0878/2
bin
C0870/2
2
1000
HIGH = inhibit controller
DCTRL-TRIP-SET
d
C0878/3
bin
C0871
2
54
HIGH = fault indication EEr
DCTRL-TRIP-RESET
d
C0878/4
bin
C0876
2
55
LOW-HIGH signal = Trip reset
DCTRL-PAR*1
d
C0884/1
bin
C0880/1
2
1000
Selecting a parameter set
DCTRL-PAR*2
d
C0884/2
bin
C0880/2
2
1000
Selecting a parameter set
DCTRL-PAR-LOAD
d
C0884/3
bin
C0881
2
1000
LOW-HIGH edge = Loading a parameter set
DCTRL-QSP
d
-
-
-
-
-
HIGH = drive performs quick stop
DCTRL-RDY
d
-
-
-
-
-
HIGH = Ready for operation
DCTRL-CINH
d
-
-
-
-
-
HIGH = Controller reset
DCTRL-IMP
d
-
-
-
-
-
HIGH = High-resistance power output
stages
DCTRL-TRIP
d
-
-
-
-
-
HIGH = Active fault
DCTRL-WARN
d
-
-
-
-
-
HIGH = Active warning
DCTRL-MESS
d
-
-
-
-
-
HIGH = Active message
DCTRL-FAIL
d
-
-
-
-
-
-
DCTRL-CW/CCW
d
-
-
-
-
-
LOW = CW rotation, HIGH = CCW rotation
DCTRL-NACT=0
d
-
-
-
-
-
HIGH = Motor speed < C0019
DCTRL-STAT*1
d
-
-
-
-
-
general status (binary coded)
DCTRL-STAT*2
d
-
-
-
-
-
general status (binary coded)
DCTRL-STAT*4
d
-
-
-
-
-
general status (binary coded)
DCTRL-STAT*8
d
-
-
-
-
-
general status (binary coded)
DCTRL-INIT
d
-
-
-
-
-
-
DCTRL-PARBUSY
d
-
-
-
-
HIGH = parameter set changeover is active
DCTRL-PAR*1-O
d
-
-
-
-
-
Parameter set X is active (binary coded)
DCTRL-PAR*2-0
d
-
-
-
-
-
Parameter set X is active (binary coded)
Function
z
Quick stop (QSP)
z
Operation inhibited (DISABLE)
z
Controller inhibit (CINH)
z
TRIP-set
z
TRIP-RESET
z
Change of parameter set (PAR)
z
Controller state
9.2.24.1
Quick stop (QSP)
The drive is braked to standstill via the deceleration ramp C105 and generates a holding torque.
z
The function can be controlled by three inputs
– Control word CAN-CTRL bit 3 of CAN-IN1
– Control word AIF-CTRL bit 3 of AIF-IN
– Control word C0135 bit 3
z
All inputs are linked by an OR-operation.
z
C0136/1 displays the control word C0135
Summary of Contents for EVS 9300 series
Page 1: ...L System Manual EDSVS9332S 31S Global Drive 9300 servo inverter 31S...
Page 28: ...Contents ii L EDSVS9332S B EN 3 0...
Page 38: ...Technical data 3 6 Dimensions 3 10 L EDSVS9332S B EN 3 0...
Page 90: ...Contents ii L EDSVS9332S C EN 3 0...
Page 108: ...During operation Operating notes 6 6 l EDSVS9332S C EN 3 0...
Page 114: ...Contents iv L EDSVS9332S D11 EN 3 0...
Page 378: ...Contents ii L EDSVS9332S D12 EN 3 0...
Page 452: ...Contents ii L EDSVS9332S E EN 3 0...
Page 466: ...Contents ii L EDSVS9332S K EN 3 0...
Page 467: ...Selection help 11 1 l EDSVS9332S K EN 3 0 Part K 11 Selection help 11 1 See folder Planning...
Page 468: ...Selection help 11 2 l EDSVS9332S K EN 3 0...
Page 485: ...Contents i L EDSVS9332S L EN 3 0 13 Signal flow diagrams 13 1...
Page 486: ...Contents ii L EDSVS9332S L EN 3 0...
Page 488: ...Signal flow charts 13 2 L EDSVS9332S L EN 3 0...
Page 491: ...Contents i L EDSVS9332S M EN 3 0 14 Glossary 14 1 14 1 Index 14 3...
Page 492: ...Contents ii L EDSVS9332S M EN 3 0...