Function library
Monitorings
9.3.3
Monitoring functions
9-221
L
EDSVS9332S-D11 EN 3.0
9.3.3
Monitoring functions
Overview of the error sources detected by the controller and the corresponding reactions
Error code
Meaning
TRIP
Message
Warning
Off
Code
CCr
System error
•
-
-
-
-
CE0
Communication error (AIF)
9
-
9
•
C0126
CE1
Communication error at the process data input object
CAN-IN1 (time monitoring can be set under C0357/1)
9
-
9
•
C0591
CE2
Communication error at the process data input object
CAN-IN2 (time monitoring can be set under C0357/2)
9
-
9
•
C0592
CE3
Communication error at the process data input object
CAN-IN3 (time monitoring can be set under C0357/3)
9
-
9
•
C0593
CE4
BUS-OFF state (many communication errors have occurred)
9
-
9
•
C0595
EEr
External monitoring
•
9
9
9
C0581
H05, H07
Internal error
•
-
-
-
-
H10
Sensor error - heatsink temperature
•
-
9
9
C0588
H11
Sensor error - internal temperature
•
-
9
9
C0588
LP1
Motor phase failure detection (function block must be
entered in C0465)
9
-
9
•
C0597
LU
Undervoltage
-
•
-
-
-
Nmax
Maximum speed exceeded (C0596)
•
-
-
-
-
nErr
Speed monitoring
9
9
9
•
C0576
OC1
Short circuit
•
-
-
-
-
OC2
Earth fault
•
-
-
-
-
OC5
I x t overload
•
-
-
-
-
OH
Heatsink temperature 1 (max. permissible, fixed)
•
-
-
-
-
OH3
Motor temperature 1 (max. permissible, fixed)
•
-
-
9
C0583
OH4
Heatsink temperature 2 (adjustable; C0122)
-
-
•
9
C0582
OH7
Motor temperature 2 (can be set; code: C0121)
-
-
•
9
C0584
OH8
Motor temperature (fixed) via inputs T1/T2
9
-
9
*
•
C0585
OU
Overvoltage in the DC bus
-
•
-
-
-
P01
Limit switch negative = LOW
9
-
-
-
C1285/1
P02
Limit switch positive = LOW
9
-
-
-
C1285/2
P03
Following error - digital frequency > C0255
9
-
•
9
C0589
P04
Position limit exceeded in negative direction
9
-
-
-
C1285/3
P05
Position limit exceeded in positive direction
9
-
-
-
C1285/4
P06
No reference
9
-
-
-
C1287/1
P07
Parameter set mode absolute
9
-
-
-
C1291/1
P08
Actual offset out of range
9
-
-
-
C1291/2
P09
Impermissible programming
9
-
-
-
C1291/3
P12
Encoder range exceeded
9
-
-
-
C1288/1
P13
Phase overflow
•
-
9
9
C0590
P14
1st following error POS > C1218/1
9
-
9
9
C1286/1
P15
2nd following error POS > C1218/2
9
-
9
•
C1286/2
P16
Sync error
9
-
9
9
C1290/1
P17
TP control error
9
-
9
9
C1289/1
P18
Internal limitation
9
-
•
9
C1289/2
Summary of Contents for EVS 9300 series
Page 1: ...L System Manual EDSVS9332S 31S Global Drive 9300 servo inverter 31S...
Page 28: ...Contents ii L EDSVS9332S B EN 3 0...
Page 38: ...Technical data 3 6 Dimensions 3 10 L EDSVS9332S B EN 3 0...
Page 90: ...Contents ii L EDSVS9332S C EN 3 0...
Page 108: ...During operation Operating notes 6 6 l EDSVS9332S C EN 3 0...
Page 114: ...Contents iv L EDSVS9332S D11 EN 3 0...
Page 378: ...Contents ii L EDSVS9332S D12 EN 3 0...
Page 452: ...Contents ii L EDSVS9332S E EN 3 0...
Page 466: ...Contents ii L EDSVS9332S K EN 3 0...
Page 467: ...Selection help 11 1 l EDSVS9332S K EN 3 0 Part K 11 Selection help 11 1 See folder Planning...
Page 468: ...Selection help 11 2 l EDSVS9332S K EN 3 0...
Page 485: ...Contents i L EDSVS9332S L EN 3 0 13 Signal flow diagrams 13 1...
Page 486: ...Contents ii L EDSVS9332S L EN 3 0...
Page 488: ...Signal flow charts 13 2 L EDSVS9332S L EN 3 0...
Page 491: ...Contents i L EDSVS9332S M EN 3 0 14 Glossary 14 1 14 1 Index 14 3...
Page 492: ...Contents ii L EDSVS9332S M EN 3 0...