Installation
Mechanical installation
4.1.3
Thermally separated mounting (push-through technique)
4-14
L
EDSVS9332S-B EN 3.0
Types 9321 ... 9326
c
b
d
e
g
Lenze
c
a
1
d1
d1
f
b1
Fig. 4-2
Dimensions for assembly with thermally separated power stage
Type
a
b
b1
c
c1
d
d1
e*
f
g
9321, 9322
112.5
385.5
350
60
95.5
365.5
105.5
250
92
6.5
9323, 9324
131.5
385.5
350
79
114.5
365.5
105.5
250
92
6.5
9325, 9226
169.5
385.5
350
117
152.5
365.5
105.5
250
92
6.5
*
When using a plug-on fieldbus module, please observe free space required for the connection cable
All dimensions in mm
Assembly cut-out
Type
Height
Width
9321, 9322
350 mm ±3 mm
82 mm ±3 mm
9323, 9324
350 mm ±3 mm
101 mm ±3 mm
9325, 9326
350 mm ±3 mm
139 mm ±3 mm
Summary of Contents for EVS 9300 series
Page 1: ...L System Manual EDSVS9332S 31S Global Drive 9300 servo inverter 31S...
Page 28: ...Contents ii L EDSVS9332S B EN 3 0...
Page 38: ...Technical data 3 6 Dimensions 3 10 L EDSVS9332S B EN 3 0...
Page 90: ...Contents ii L EDSVS9332S C EN 3 0...
Page 108: ...During operation Operating notes 6 6 l EDSVS9332S C EN 3 0...
Page 114: ...Contents iv L EDSVS9332S D11 EN 3 0...
Page 378: ...Contents ii L EDSVS9332S D12 EN 3 0...
Page 452: ...Contents ii L EDSVS9332S E EN 3 0...
Page 466: ...Contents ii L EDSVS9332S K EN 3 0...
Page 467: ...Selection help 11 1 l EDSVS9332S K EN 3 0 Part K 11 Selection help 11 1 See folder Planning...
Page 468: ...Selection help 11 2 l EDSVS9332S K EN 3 0...
Page 485: ...Contents i L EDSVS9332S L EN 3 0 13 Signal flow diagrams 13 1...
Page 486: ...Contents ii L EDSVS9332S L EN 3 0...
Page 488: ...Signal flow charts 13 2 L EDSVS9332S L EN 3 0...
Page 491: ...Contents i L EDSVS9332S M EN 3 0 14 Glossary 14 1 14 1 Index 14 3...
Page 492: ...Contents ii L EDSVS9332S M EN 3 0...