Configuration
Basic configurations
8.2.1
Speed control C0005 = 1XXX (1000)
8-8
L
EDSVS9332S-D11 EN 3.0
Stop the controller via trip (TRIP-SET)
The controller can be stopped via the monitoring function when the LOW signal is applied at terminal
X5/E4. This input is mainly used to evalulate external binary encoders.
The reaction on this input signal can be programmed.
(see chapter 9.2.24.4)
Fault reset (TRIP-RESET)
After the cause of fault has been eliminated, a trip can be reset with a LOW-HIGH edge at terminal
X5/E5.