Function library
Function blocks
9.2.41
Mains failure control (MFAIL)
9-145
L
EDSVS9332S-D11 EN 3.0
9.2.41
Mains failure control (MFAIL)
Purpose
If the supply voltage via L1, L2, L3 or +UG, -UG fails, the drive (drive network) can be decelerated
(braked) in a controlled way. Without this function, the drive would coast.
C0988/7
MFAIL-DC-SET
C0989/1
MFAIL-FAULT
MFAIL-RESET
C0982
C0971
C0972
C0978
MFAIL-ADAPT
C988/2
C0973
C0974
C0981
+
-
1
0
C0988/1
C0970
MFAIL-CONST
C988/3
C0980 Vp
Tn
MCRTL-
DCVOLT
C0989/2
MFAIL-THRESHOLD
C0975
C0988/4
MFAIL-NACT
C0976
C0988/5
MFAIL-SET
C0977
C0988/6
CTRL
MFAIL-I-RESET
MFAIL-NOUT
MFAIL-STATUS
MFAIL
+
-
MFAIL-N-SET
C0983
Fig. 9-98
Mains failure control (MFAIL)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
MFAIL-N-SET
a
C0988/1
dec [%]
C0970
1
1000
Speed setpoint in [%] of C0011
MFAIL-ADAPT
a
C0988/2
dec [%]
C0973
1
1000
Dynamic adaptation of the proportional
gain of the UGset controller in [%] of
C0980
MFAIL-CONST
a
C0988/3
dec [%]
C0974
1
1000
Proportional gain of the U
Gset
controller in
[%] of C0980
MFAIL-THRESHOLD
a
C0988/4
dec [%]
C0975
1
1000
Restart threshold in [%] of C0011
MFAIL-NACT
a
C0988/5
dec [%]
C0976
1
1000
Comparison value for the restart threshold
in [%] of C0011
MFAIL-SET
a
C0988/6
dec [%]
C0977
1
1000
Speed start point for the deceleration in
[%] of C0011
MFAIL-DC-SET
a
C0988/7
dec [%]
C0978
1
1000
Voltage setpoint on which the DC bus
voltage is to be maintained, 100% =
1000V
MFAIL-FAULT
d
C0989/1
bin
C0971
2
1000
HIGH = activates the mains failure control
MFAIL-RESET
d
C0989/2
bin
C0972
2
1000
HIGH = reset
MFAIL-N-OUT
a
-
-
-
-
-
Speed setpoint in [%] of C0011
MFAIL-STATUS
d
-
-
-
-
-
HIGH = mains failure control active
MFAIL-I-RESET
d
-
-
-
-
-
HIGH = mains failure control active, the
drive is braking
Summary of Contents for EVS 9300 series
Page 1: ...L System Manual EDSVS9332S 31S Global Drive 9300 servo inverter 31S...
Page 28: ...Contents ii L EDSVS9332S B EN 3 0...
Page 38: ...Technical data 3 6 Dimensions 3 10 L EDSVS9332S B EN 3 0...
Page 90: ...Contents ii L EDSVS9332S C EN 3 0...
Page 108: ...During operation Operating notes 6 6 l EDSVS9332S C EN 3 0...
Page 114: ...Contents iv L EDSVS9332S D11 EN 3 0...
Page 378: ...Contents ii L EDSVS9332S D12 EN 3 0...
Page 452: ...Contents ii L EDSVS9332S E EN 3 0...
Page 466: ...Contents ii L EDSVS9332S K EN 3 0...
Page 467: ...Selection help 11 1 l EDSVS9332S K EN 3 0 Part K 11 Selection help 11 1 See folder Planning...
Page 468: ...Selection help 11 2 l EDSVS9332S K EN 3 0...
Page 485: ...Contents i L EDSVS9332S L EN 3 0 13 Signal flow diagrams 13 1...
Page 486: ...Contents ii L EDSVS9332S L EN 3 0...
Page 488: ...Signal flow charts 13 2 L EDSVS9332S L EN 3 0...
Page 491: ...Contents i L EDSVS9332S M EN 3 0 14 Glossary 14 1 14 1 Index 14 3...