Technical data
3.3
Rated data
3-5
L
EDSVS9332S-B EN 3.0
3.3.2
Types 9321 to 9324 with 200% overcurrent
Type
EVS9321-ES
EVS9322-ES
EVS9323-ES
EVS9324-ES
Order No.
EVS9321-ES
EVS9322-ES
EVS9323-ES
EVS9324-ES
Data for the operation on a mains: 3 AC/400 V / 50 Hz/60 Hz
Motor power (4-pole ASM)
P
r
[kW]
0.37
0.75
1.5
3.0
Motor power (4 pole ASM)
P
r
[hp]
0.5
1.0
2.0
4.0
Output power U, V, W (8 kHz)
S
r8
[kVA]
1.0
1.7
2.7
4.8
Output current (8 kHz)
2)
I
r8
[A]
1.5
2.5
3.9
7.0
Output current (16 kHz)
2)
I
r16
[A]
1.1
1.8
2.9
5.2
Max. output current (8 kHz)
1)
I
max8
[A]
3.0
5.0
7.8
14.0
Max. output current (16 kHz)
1)
I
max16
[A]
2.2
3.6
5.8
10.4
Max. standstill current (8 kHz)
I
08
[A]
3.0
5.0
7.8
14.0
Max. standstill current (16 kHz)
I
016
[A]
2.2
3.6
5.8
10.4
Data for the operation on a mains: 3 AC/480 V / 50 Hz/60 Hz
Motor power (4-pole ASM)
P
r
[kW]
0.37
0.75
1.5
3.0
Motor power (4 pole ASM)
P
r
[hp]
0.5
1.0
2.0
4.0
Output power U, V, W (8 kHz)
S
r8
[kVA]
1.2
2.1
3.2
5.8
Output current (8 kHz)
2)
I
r8
[A]
1.5
2.5
3.9
7.0
Output current (16 kHz)
2)
I
r16
[A]
1.1
1.8
2.9
5.2
Max. output current (8 kHz)
1)
I
max8
[A]
3.0
5.0
7.8
14.0
Max. output current (16 kHz)
1)
I
max16
[A]
2.2
3.6
5.8
10.4
Max. standstill current (8 kHz)
I
08
[A]
3.0
5.0
7.8
14.0
Max. standstill current (16 kHz)
I
016
[A]
2.2
3.6
5.8
10.4
1)
The currents apply to a periodical load cycle with 10 seconds overcurrent with the current mentioned here and
50 seconds base load with 44 % I
rx
Majority in indiv. cases
Setting in C0022
Thermal
continuous current
Maximum current
phase
Recovery phase
Continuous power
I
max
≤
150 % I
rx
100 % I
rx
150 % I
rx
for 60 s
75 % I
rx
for 120 s
Peak power
I
max
>150 % I
rx
70 % I
rx
200 % I
rx
for 10 s
44 % I
rx
for 50 s
2)
This output current Irx applies to a maximum current to be set under C022 which has not exceeded 150% of the
rated controller current (nameplate).
If the maximum current is higher than this value, the continuous current automatically decreases to 70% of the
original value.
Overcurrent diagram:
6-5
All other data:
3-4
Tip!
You can switch to I
max
> 150 % I
rx
only if the controller is inhibited.
Summary of Contents for EVS 9300 series
Page 1: ...L System Manual EDSVS9332S 31S Global Drive 9300 servo inverter 31S...
Page 28: ...Contents ii L EDSVS9332S B EN 3 0...
Page 38: ...Technical data 3 6 Dimensions 3 10 L EDSVS9332S B EN 3 0...
Page 90: ...Contents ii L EDSVS9332S C EN 3 0...
Page 108: ...During operation Operating notes 6 6 l EDSVS9332S C EN 3 0...
Page 114: ...Contents iv L EDSVS9332S D11 EN 3 0...
Page 378: ...Contents ii L EDSVS9332S D12 EN 3 0...
Page 452: ...Contents ii L EDSVS9332S E EN 3 0...
Page 466: ...Contents ii L EDSVS9332S K EN 3 0...
Page 467: ...Selection help 11 1 l EDSVS9332S K EN 3 0 Part K 11 Selection help 11 1 See folder Planning...
Page 468: ...Selection help 11 2 l EDSVS9332S K EN 3 0...
Page 485: ...Contents i L EDSVS9332S L EN 3 0 13 Signal flow diagrams 13 1...
Page 486: ...Contents ii L EDSVS9332S L EN 3 0...
Page 488: ...Signal flow charts 13 2 L EDSVS9332S L EN 3 0...
Page 491: ...Contents i L EDSVS9332S M EN 3 0 14 Glossary 14 1 14 1 Index 14 3...
Page 492: ...Contents ii L EDSVS9332S M EN 3 0...