Function library
Function blocks
9.2.46
Speed setpoint conditioning (NSET)
9-164
L
EDSVS9332S-D11 EN 3.0
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
NSET-N
O
C0046
dec [%]
C0780
1
50
Intended for main setpoint, other signals
are permissible
NSET-NADD
O
C0047
dec [%]
C0782
1
5650
Intended for additional setpoint, other
signals are permissible
NSET-JOG*1
d
C0799/4
bin
C0787/1
2
53
Selection and control of overriding ”fixed
NSET-JOG*2
d
C0799/5
bin
C0787/2
2
1000
Selection and control of overriding fixed
setpoints” for the main setpoint
NSET-JOG*4
d
C0799/6
bin
C0787/3
2
1000
NSET-JOG*8
d
C0799/7
bin
C0787/4
2
1000
NSET-TI*1
d
C0799/8
bin
C0788/1
2
1000
Selection and control of alternative
NSET-TI*2
d
C0799/9
bin
C0788/2
2
1000
Selection and control of alternative
acceleration and deceleration times for the
main setpoint
NSET-TI*4
d
C0799/10
bin
C0788/3
2
1000
main setpoint
NSET-TI*8
d
C0799/11
bin
C0788/4
2
1000
NSET-N-INV
d
C0799/1
bin
C0781
2
10251
Control of the signal inversion for the main
setpoint
NSET-NADD-INV
d
C0799/2
bin
C0783
2
1000
Control of the signal inversion for the
additional setpoint
NSET-RFG-0
d
C0799/12
bin
C0789
2
1000
The main setpoint integrator is led to zero
via the current T
i
times.
NSET-RFG-STOP
d
C0799/13
bin
C0790
2
1000
Keeping (freezing) of the main setpoint
integrator to its actual value.
NSET-CINH-VAL
O
C0798/1
dec [%]
C0784
1
5001
Here, the signal is applied which is to be
accepted by the main setpoint integrator
when the controller is inhibited
NSET-SET
O
C0798/2
dec [%]
C0785
1
5000
Here, the signal is applied which is to be
accepted by the main setpoint integrator
when the NSET-LOAD input is set
NSET-LOAD
d
C0799/3
bin
C0786
2
5001
Control of both ramp function generators in
special situations, e.g. QSP
NSET-OUT
O
-
-
-
-
-
-
NSET-RFG-I=0
d
-
-
-
-
-
-
Function
z
Main setpoint path
z
JOG setpoints
z
Setpoint inversion
z
S ramp
9.2.46.1
Main setpoint path
z
The signals in the main setpoint path are limited to the value range ±199.99 % .
z
The signal at input NSET-N is led via the function JOG selection.
z
The JOG function has priority over the setpoint input NSET-N. This means a selected JOG
value deactivates the input. The subsequent signal conditioning the JOG value instead.
Summary of Contents for EVS 9300 series
Page 1: ...L System Manual EDSVS9332S 31S Global Drive 9300 servo inverter 31S...
Page 28: ...Contents ii L EDSVS9332S B EN 3 0...
Page 38: ...Technical data 3 6 Dimensions 3 10 L EDSVS9332S B EN 3 0...
Page 90: ...Contents ii L EDSVS9332S C EN 3 0...
Page 108: ...During operation Operating notes 6 6 l EDSVS9332S C EN 3 0...
Page 114: ...Contents iv L EDSVS9332S D11 EN 3 0...
Page 378: ...Contents ii L EDSVS9332S D12 EN 3 0...
Page 452: ...Contents ii L EDSVS9332S E EN 3 0...
Page 466: ...Contents ii L EDSVS9332S K EN 3 0...
Page 467: ...Selection help 11 1 l EDSVS9332S K EN 3 0 Part K 11 Selection help 11 1 See folder Planning...
Page 468: ...Selection help 11 2 l EDSVS9332S K EN 3 0...
Page 485: ...Contents i L EDSVS9332S L EN 3 0 13 Signal flow diagrams 13 1...
Page 486: ...Contents ii L EDSVS9332S L EN 3 0...
Page 488: ...Signal flow charts 13 2 L EDSVS9332S L EN 3 0...
Page 491: ...Contents i L EDSVS9332S M EN 3 0 14 Glossary 14 1 14 1 Index 14 3...
Page 492: ...Contents ii L EDSVS9332S M EN 3 0...