Troubleshooting and fault elimination
10.3
Fault messages
10-7
L
EDSVS9332S-E EN 3.0
Error
code
Remedy
Cause
Error
Fault number
x = 0: TRIP
x = 1: Message
x = 2: Warning
OC1
x011
Short circuit
Short circuit.
Search for cause of short circuit; check cable.
OC1
x011
Short circuit
Excessive capacitive charging current of the motor
cable.
Use motor cable which is shorter or of lower
capacitance.
OC2
x012
Earth fault
One of the motor phases has earth contact.
•
Check motor
•
Check supply module
Excessive capacitive charging current of the motor
cable.
Use motor cable which is shorter or of lower
capacitance.
OC5
x015
I x t overload
Frequent and overlong acceleration with overcurrent
Permanent overload with I
motor
> 1.05 × I
Nx.
Check drive dimensioning.
OH
x050
Heatsink temperature is
higher than the value set
in the controller
Ambient temperature T
amb
> 40 °C or 50 °C.
•
Allow controller to cool and ensure better
ventilation.
•
Check ambient temperature in the control
cabinet.
Heatsink very dirty.
Clean heatsink
Incorrect mounting position.
Change mounting position.
OH3
1)
x053
Heatsink temperature is
higher than the value set
Motor too hot because of excessive current or
frequent and overlong acceleration
Check drive dimensioning.
higher than the value set
in the controller
No PTC connected.
Connect PTC or switch-off monitoring (C0583 = 3).
OH4
x054
Heatsink temperature is
higher than the value set
under C0122.
Ambient temperature T
amb
> 40 °C or 50 °C.
•
Allow controller to cool and ensure better
ventilation.
•
Check ambient temperature in the control
cabinet.
Heatsink very dirty.
Clean heatsink
Incorrect mounting position.
Change mounting position.
Value set under C0122 was too low.
Enter higher value.
OH7
1)
x057
Motor temperature is
higher than the value set
Motor too hot because of excessive current or
frequent and overlong acceleration
Check drive dimensioning.
higher than the value set
under C0121.
No PTC connected.
Connect PTC or switch-off monitoring (C0584 = 3).
Value set under C0121 was too low.
Enter higher value.
OH8
x058
PTC at terminals T1, T2
indicates motor
Motor too hot because of excessive current or
frequent and overlong acceleration
Check drive dimensioning.
indicates motor
overheat.
Terminals T1, T2 are not assigned.
Connect PTC or thermostat or switch off monitoring
(C0585=3).
OU
x020
Overvoltage
Excessive brake energy (DC bus voltage higher than
set under C0173).
Use brake module or energy recovery module.
P01
x151
Limit switch negative
Negative limit switch was reached.
•
Control drive in positive direction
•
Check terminal connection X5/E2.
P02
x152
Positive limit switch
Positive limit switch was reached.
•
Control drive in negative direction
•
Check terminal connection X5/E1.
P03
x153
Following error
Phase difference between set and actual position is
larger than the following error limit set under
C0255.
•
Extend following error limit under C0255
•
Switch off the monitoring if necessary
(C0589 = 3).
Drive cannot follow the digital frequency (I
max
limit). Check drive dimensioning.
P04
x154
Negative position limit
Negative position limit (C1224) was not reached.
Before starting again, find out why the limit was not
reached (e.g. ”incorrect” position targets, setting of
position value function) and adapt the negative
position limit (C1224).
P05
x155
Positive position limit
Positive position limit (C1223) was exceeded.
Find out why the value was exceeded (e.g.
”incorrect” position targets, set function position
value) and adjust the positive position limit (C1223)
if necessary.
P06
x156
No reference
The reference point is not known. In case of the
absolute positioning, no homing was carried out
before the first positioning.
Perform one of the following functions and restart:
•
Manual homing.
•
Start homing in the program.
•
Set reference.
P07
x157
PS Absolute mode
instead of relative mode.
An absolute PS (C1311) was performed during
relative positioning (position mode C1210).
Perform one of the following functions and restart:
•
Change from absolute PS to relative PS.
•
Change position mode.
P08
x158
Actual offset out of
range
Actual reference dimension offset (C1226) outside
the position limits. Error of the program function
”set position value”.
If necessary, adapt the position limit values or
check whether the program function ”set position
value” is to be applied.
Summary of Contents for EVS 9300 series
Page 1: ...L System Manual EDSVS9332S 31S Global Drive 9300 servo inverter 31S...
Page 28: ...Contents ii L EDSVS9332S B EN 3 0...
Page 38: ...Technical data 3 6 Dimensions 3 10 L EDSVS9332S B EN 3 0...
Page 90: ...Contents ii L EDSVS9332S C EN 3 0...
Page 108: ...During operation Operating notes 6 6 l EDSVS9332S C EN 3 0...
Page 114: ...Contents iv L EDSVS9332S D11 EN 3 0...
Page 378: ...Contents ii L EDSVS9332S D12 EN 3 0...
Page 452: ...Contents ii L EDSVS9332S E EN 3 0...
Page 466: ...Contents ii L EDSVS9332S K EN 3 0...
Page 467: ...Selection help 11 1 l EDSVS9332S K EN 3 0 Part K 11 Selection help 11 1 See folder Planning...
Page 468: ...Selection help 11 2 l EDSVS9332S K EN 3 0...
Page 485: ...Contents i L EDSVS9332S L EN 3 0 13 Signal flow diagrams 13 1...
Page 486: ...Contents ii L EDSVS9332S L EN 3 0...
Page 488: ...Signal flow charts 13 2 L EDSVS9332S L EN 3 0...
Page 491: ...Contents i L EDSVS9332S M EN 3 0 14 Glossary 14 1 14 1 Index 14 3...
Page 492: ...Contents ii L EDSVS9332S M EN 3 0...