Function library
Code table
9-257
l
EDSVS9332S-D12 EN 3.0
Code
Important
Possible settings
No.
Selection
Lenze
LCD
C0034 MST CURRENT
0
0
1
2
-10 V ... + 10 V
+4 mA ... +20 mA
-20 mA ... +20 mA
Master reference voltage / current
Selection for setpoint selection
C0037 SET-VALUE RPM
0
-16000
{1 rpm}
16000
Setpoint selection (rpm)
C0039
-199.99
{0.01 %}
199.99
NSET JOG setpoints
1 JOG SET-VALUE
100.00
p
Fixed speeds (JOG setpoints) can be selected
for NSET using digital inputs
2 JOG SET-VALUE
75.00
for NSET using digital inputs
3 JOG SET-VALUE
50.00
4 JOG SET-VALUE
25.00
5 JOG SET-VALUE
0.00
... ...
...
14 JOG SET-VALUE
0.00
15 JOG SET-VALUE
0.00
C0040 CTRL ENABLE
1
0
1
Controller inhibited
Controller enabled
Controller enable RFR
C0042 QSP
1
2
QSP: Not active
QSP: Active
Quick stop
C0043 TRIP RESET
0
0
1
TRIP RESET
Active error
Error reset
Reset of an active trip:
Set C0043 = 0
C0045 ACT JOG
0
1
2
...
15
Nset active
JOG 1
JOG 2
...
JOG 15
NSET
JOG selection
C0046 NSET-N
-199.99
{0.01 %}
199.99
NSET
Main setpoint
C0049 NSET-NADD
-199.99
{0.01 %}
199.99
NSET
Additional setpoint
C0050 MCTRL-NSET2
-100.00
{0.01 %}
100.00
MCTRL
n
set
at speed controller input
C0051 MCTRL-NACT
-30000
{1 rpm}
30000
Actual speed value
C0052 MCTRL-UMOT
0
{1 V}
800
Motor voltage
C0053 UG-VOLTAGE
0
{1 V}
900
DC-bus voltage
C0054 IMOT
0.0
{0.1 A}
500.0
Imot (motor current)
C0056 MCTRL-MSET2
-100.00
{0.01 %}
100.00
MCTRL
Torque setpoint (controller output with torque
precontrol (MCTRL-M-ADD)
C0057 MAX TORQUE
0
{1 Nm}
500
Maximum torque (C0086/C0022)
Maximum possible torque of the drive
configuration
depending on C0022, C0086
C0058 ROTOR DIFF
-90.o
-180.0
{0.1 °}
179.9
Rotor displacement angle
Zero phase of the rotor for synchronous motors
(C0095)
C0059 MOT POLE NO.
1
{1}
50
Number of motor pole pairs
C0060 ROTOR POS
0
{1}
2048
Motor rotor position
1 rev. = 2048 inc
C0061 HEATSINK TEMP
0
{1 °C}
100
Heatsink temperature
C0063 MOT TEMP
0
{1 °C}
200
Motor temperature
C0064 UTILISATION
0
{1 %}
150
Device load Ixt
during the last 180 s
C0064 > 100 % releases OC5
Trip reset is possible only if C0064 < 95 %
C0067 ACT TRIP
All fault indications
Æ
Selection list 10
Error message TRIP
Momentary fault indication
Summary of Contents for EVS 9300 series
Page 1: ...L System Manual EDSVS9332S 31S Global Drive 9300 servo inverter 31S...
Page 28: ...Contents ii L EDSVS9332S B EN 3 0...
Page 38: ...Technical data 3 6 Dimensions 3 10 L EDSVS9332S B EN 3 0...
Page 90: ...Contents ii L EDSVS9332S C EN 3 0...
Page 108: ...During operation Operating notes 6 6 l EDSVS9332S C EN 3 0...
Page 114: ...Contents iv L EDSVS9332S D11 EN 3 0...
Page 378: ...Contents ii L EDSVS9332S D12 EN 3 0...
Page 452: ...Contents ii L EDSVS9332S E EN 3 0...
Page 466: ...Contents ii L EDSVS9332S K EN 3 0...
Page 467: ...Selection help 11 1 l EDSVS9332S K EN 3 0 Part K 11 Selection help 11 1 See folder Planning...
Page 468: ...Selection help 11 2 l EDSVS9332S K EN 3 0...
Page 485: ...Contents i L EDSVS9332S L EN 3 0 13 Signal flow diagrams 13 1...
Page 486: ...Contents ii L EDSVS9332S L EN 3 0...
Page 488: ...Signal flow charts 13 2 L EDSVS9332S L EN 3 0...
Page 491: ...Contents i L EDSVS9332S M EN 3 0 14 Glossary 14 1 14 1 Index 14 3...
Page 492: ...Contents ii L EDSVS9332S M EN 3 0...