Function library
Code table
9-258
l
EDSVS9332S-D12 EN 3.0
Code
Important
Possible settings
No.
Selection
Lenze
LCD
C0070 VP SPEED CTRL
→
0.0
{0.5 }
255.0
V
pn
speed controller
Æ
depending on C0086
Change of C0086 resets value to the assigned
default setting
C0071 TN SPEED CTRL
→
1.0
{0.5 ms}
600.0
T
nn
speed controller
>512 ms switched off
Æ
depending on C0086
Change of C0086 resets value to the assigned
default setting
C0072 TD SPEED CTRL
0.0
0.0
{0.1 ms}
32.0
T
dn
speed controller
C0075 VP CURR CTRL
0.35
0.00
{0.01 }
15.99
V
pi
current controller
C0076 TN CURR CTRL
1.8
0.5
{0.1 ms}
2000.0
T
ni
current controller
2000 ms switched off
C0077 VP FIELD CTRL
0.25
0.00
{0.01 }
15.99
V
pF
field controller
C0078 TN FIELD CTRL
15.0
1.0
{0.5 ms}
8000.0
T
nF
field controller
8000 ms switched off
[C0081] MOT POWER
→
0.01
{0.01 kW}
150.00
Rated motor power
acc. to nameplate
Æ
depending on C0086
Change of C0086 resets value to the assigned
default setting
Change of C0081 sets C0086 = 0
[C0084] MOT RS
→
0.00
{0.01
Ω
}
100.00
Motor stator resistance
Æ
depending on C0086
Change of C0086 resets value to the assigned
default setting
[C0085] MOT LS
→
0.00
{0.01 mH}
200.00
Motor leakage inductance
Æ
depending on C0086
Change of C0086 resets value to the assigned
default setting
[C0086] MOT TYPE
→
See motor selection list
Motor type selection
Æ
depending on the controller used
Change of C0086 resets C0006, C0022, C0070,
C0071, C0081, C0084, C0085, C0087, C0088,
C0089, C0090, C0091 to the assigned default
setting
[C0087] MOT SPEED
→
300
{1 rpm}
16000
Rated motor speed
Æ
depending on C0086
Change of C0086 resets value to the assigned
default setting
[C0088] MOT CURRENT
→
0.5
{0.1 A}
300.0
Rated motor current
Æ
depending on C0086
Change of C0086 resets value to the assigned
default setting
[C0089] MOT FREQUENCY
→
10
{1 Hz}
1000
Rated motor frequency
[C0090] MOT VOLTAGE
→
50
{1 V}
500
Rated motor voltage
Æ
depending on C0086
Change of C0086 resets value to the assigned
default setting
[C0091] MOT COS PHI
→
0.50
{0.01 }
1.00
Motor cos
ϕ
Æ
depending on C0086
Change of C0086 resets value to the assigned
default setting
C0093 DRIVE IDENT
0
1
93xx
damaged power section
no power section
93xx
Controller identification
93xx: Lenze servo inverter
C0094 PASSWORD
0
0
{1}
9999
Password
Parameter access protection for the keypad XT.
If the password is activated, only the codes of
the user menu can be accessed. For further
possible selections see C0096
Summary of Contents for EVS 9300 series
Page 1: ...L System Manual EDSVS9332S 31S Global Drive 9300 servo inverter 31S...
Page 28: ...Contents ii L EDSVS9332S B EN 3 0...
Page 38: ...Technical data 3 6 Dimensions 3 10 L EDSVS9332S B EN 3 0...
Page 90: ...Contents ii L EDSVS9332S C EN 3 0...
Page 108: ...During operation Operating notes 6 6 l EDSVS9332S C EN 3 0...
Page 114: ...Contents iv L EDSVS9332S D11 EN 3 0...
Page 378: ...Contents ii L EDSVS9332S D12 EN 3 0...
Page 452: ...Contents ii L EDSVS9332S E EN 3 0...
Page 466: ...Contents ii L EDSVS9332S K EN 3 0...
Page 467: ...Selection help 11 1 l EDSVS9332S K EN 3 0 Part K 11 Selection help 11 1 See folder Planning...
Page 468: ...Selection help 11 2 l EDSVS9332S K EN 3 0...
Page 485: ...Contents i L EDSVS9332S L EN 3 0 13 Signal flow diagrams 13 1...
Page 486: ...Contents ii L EDSVS9332S L EN 3 0...
Page 488: ...Signal flow charts 13 2 L EDSVS9332S L EN 3 0...
Page 491: ...Contents i L EDSVS9332S M EN 3 0 14 Glossary 14 1 14 1 Index 14 3...
Page 492: ...Contents ii L EDSVS9332S M EN 3 0...