666
G8332 Command Reference for ENOS 8.4
Precision Time Protocol Configuration
Precision
Time
Protocol
(PTP)
allows
high
accuracy
clock
synchronization
between
a
networked
master
clock
and
compliant
network
hosts.
The
Lenovo
RackSwitch
G8332
supports
two
PTP
modes:
Ordinary
slave
clock
‐
Synchronizes
the
Real
Time
Clock
(RTC)
with
PTP
master
clocks
detected
on
the
network.
End
‐
to
‐
End
transparent
clock
‐
Allows
PTP
traffic
to
pass
through
without
affecting
the
RTC,
while
updating
the
correction
fields
for
event
packets.
Table 380.
Precision
Time
Protocol
Configuration
Options
Command Syntax and Usage
[no]
ptp
ordinary
enable
Enables
or
disables
PTP
ordinary
slave
clock
mode.
In
this
mode,
if
a
PTP
master
clock
is
detected
on
the
network,
the
RTC
is
synchronized
with
it.
If
no
master
clock
is
detected,
the
RTC
is
not
affected.
The
default
setting
is
disabled
.
Note:
Enabling
PTP
ordinary
slave
clock
mode
disables
NTP
settings
and
system
time
clock
manual
settings.
Command
mode:
Global
configuration
[no]
ptp
transparent
enable
Enables
or
disables
PTP
End
‐
to
‐
End
transparent
clock
mode.
In
this
mode,
incoming
PTP
packets
are
forwarded
based
on
routing
rules
currently
in
place
for
the
PTP
domain’s
multicast
address
(within
the
224.0.1.129
‐
224.0.1.132
range).
On
egress,
PTP
packet
timestamps
are
updated
based
on
the
time
spent
between
ingress
and
egress.
The
default
setting
is
disabled
.
Command
mode:
Global
configuration
ip
ptp
source
interface
loopback
<1
‐
5>
Loopback
interface
used
as
source
IP
address
for
delay
‐
request
packets
sent
during
synchronization
with
the
master
clock
in
ordinary
slave
mode.
By
default,
the
interface
with
the
lowest
index
from
the
master
clock’s
VLAN
is
used.
Command
mode:
Global
configuration
no
ip
ptp
source
interface
loopback
Sets
source
IP
address
for
delay
‐
request
packets
sent
during
synchronization
with
the
master
clock
in
ordinary
slave
mode
to
the
interface
with
the
lowest
index
from
the
master
clock’s
VLAN.
Command
mode
:
Global
configuration
no
ptp
Disables
both
PTP
ordinary
slave
clock
mode
and
PTP
End
‐
to
‐
End
transparent
clock
mode.
Command
mode:
Global
configuration
Summary of Contents for RackSwitch G8332
Page 20: ...20 G8332 Command Reference for ENOS 8 4 ...
Page 32: ...32 G8332 Command Reference for ENOS 8 4 ...
Page 674: ...674 G8332 Command Reference for ENOS 8 4 ...
Page 708: ...708 G8332 Command Reference for ENOS 8 4 ...
Page 732: ...732 G8332 Command Reference for ENOS 8 4 ...
Page 750: ...750 G8332 Command Reference for ENOS 8 4 ...
Page 766: ...766 G8332 Command Reference for ENOS 8 4 Taiwan Class A compliance statement ...