G8332 Command Reference for ENOS 8.4
[no]
buffer
Enables
or
disables
buffering
support
for
OpenFlow
packets.
The
default
setting
is
disabled
.
Command
mode
:
OpenFlow
Instance
connect
retry
<1
‐
8>
Configures
the
maximum
number
of
attempts
to
establish
connection
to
a
controller,
before
assuming
the
controller
is
down.
The
default
value
is
4
.
Command
mode
:
OpenFlow
Instance
no
connect
retry
Resets
the
connect
retry
value
to
4.
Command
mode
:
OpenFlow
Instance
controller
<1
‐
4>
address
<IP
address>
[data
port|mgt
port]
Configures
the
IP
address
of
the
OpenFlow
Controller.
You
may
specify
the
port
to
use
for
data
transfer:
data
port
(
data
port
)
or
management
port
(
mgt
port
).
By
default,
the
system
uses
the
management
port.
Command
mode:
OpenFlow
Instance
controller
<1
‐
4>
port
<
TCP
port
number
(
1
‐
65535)>
Configures
the
TCP
port
used
for
communication
with
the
Controller.
The
default
port
is
6633
.
Command
mode:
OpenFlow
Instance
no
controller
<1
‐
4>
Deletes
the
selected
controller
from
the
specified
instance
ID.
Command
mode
:
OpenFlow
Instance
dpid
<hex
string>
Applies
an
8
byte
Datapath
ID
to
the
instance,
which
uniquely
identifies
an
OpenFlow
instance
in
an
OpenFlow
environment.
The
default
value
is
the
instance
ID
followed
by
the
switch
MAC.
Note:
The
Datapath
ID
must
be
unique
among
the
switches
controlled
by
a
single
OpenFlow
controller.
Command
mode
:
OpenFlow
Instance
no
dpid
Resets
the
instance’s
Datapath
ID
to
the
default
value
(instance
ID
followed
by
the
switch
MAC).
Command
mode
:
OpenFlow
Instance
Table 374.
OpenFlow
Configuration
Options
(continued)
Command Syntax and Usage
Summary of Contents for RackSwitch G8332
Page 20: ...20 G8332 Command Reference for ENOS 8 4 ...
Page 32: ...32 G8332 Command Reference for ENOS 8 4 ...
Page 674: ...674 G8332 Command Reference for ENOS 8 4 ...
Page 708: ...708 G8332 Command Reference for ENOS 8 4 ...
Page 732: ...732 G8332 Command Reference for ENOS 8 4 ...
Page 750: ...750 G8332 Command Reference for ENOS 8 4 ...
Page 766: ...766 G8332 Command Reference for ENOS 8 4 Taiwan Class A compliance statement ...