This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0401ffff or 0x816f000d0401ffff
Severity
Info
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix:
PLAT
ID:
0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4.
Check the SAS cable.
•
816f000d-0402ffff : The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 2)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0402ffff or 0x816f000d0402ffff
Severity
Info
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix:
PLAT
ID:
0163
User Response
Appendix A. Integrated management module 2.1 (IMM2.1) error messages
655
Summary of Contents for HX1310
Page 1: ...HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide Machine Type 8693 ...
Page 6: ...iv HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Page 14: ...xii HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Page 984: ...970 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Page 994: ...980 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Page 1001: ......
Page 1002: ......