![Lenovo HX1310 Installation And Service Manual Download Page 578](http://html.mh-extra.com/html/lenovo/hx1310/hx1310_installation-and-service-manual_202638578.webp)
•
806f0813-2582ffff : An Uncorrectable Bus Error has occurred on system
[ComputerSystemElementName]. (PCIs)
This message is for the use case when an implementation has detected a Bus Uncorrectable Error.
May also be shown as 806f08132582ffff or 0x806f08132582ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix:
PLAT
ID:
0240
User Response
1. Check the system-event log.
2.
Check the PCI LED.
3. Remove the adapter from the indicated PCI slot.
4. Check for a server firmware update. Important: Some cluster solutions require specific code
levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest
level of code is supported for the cluster solution before you update the code.
5. (Trained technician only) Replace the system board.
•
806f0813-2584ffff : An Uncorrectable Bus Error has occurred on system
[ComputerSystemElementName]. (CPUs)
This message is for the use case when an implementation has detected a Bus Uncorrectable Error.
May also be shown as 806f08132584ffff or 0x806f08132584ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
564
HX1310, HX2310-E, HX3310, HX3310-F Installation and Service Guide
Summary of Contents for HX1310
Page 1: ...HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide Machine Type 8693 ...
Page 6: ...iv HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Page 14: ...xii HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Page 984: ...970 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Page 994: ...980 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Page 1001: ......
Page 1002: ......