the server is powered-on locally, the active power manager active power management event signal will
be enabled by the system-board logic.
• The Intel X710 2x10GbE SFP+ Adapter supports 10-Gbps transfer rate only.
• Pay attention to the following before installing any PCI adapter.
• Pay attention to the following PCI adapter configuration table before installing any PCI adapter.
Table 30. Adapter configurations
Description
Option part
number
PCI riser 1
PCI riser 2
Intel X540 ML2 Dual Port 10GbaseT Adapter
00D1994
Seven fans required
Seven fans required
Note:
You can purchase the System x3550 M5 Fan Gen 2 (option part number: 00MV373) to acquire two
additional fans for your server.
• The server provides two PCI riser-card slots on the system board.The following table lists the supported
PCI riser-card assembly configurations in the server.
Table 31. Configuration 1 (HX1310 only)
Configuration 1
PCI riser-card assembly
connector 1 on system board
PCI riser-card assembly
connector 2 on system board
Configuration
Number of
microprocessors
installed
Slot 1
Slot 2
Slot 3
– Three
low-profile
slots
One
x1/x4/x8/x16 low-profile
x1/x4/x8
low-profile
x1/x4/x8
low-profile
Table 32. Configuration 2 (HX2310-E, HX3310, HX3310-F)
Configuration 2
PCI riser-card assembly
connector 1 on system board
PCI riser-card assembly
connector 2 on system board
Configuration
Number of
microprocessors
installed
Slot 1
Slot 2
Slot 3
– Three
low-profile
slots
Two
x1/x4/x8/x16 low-profile
x1/x4/x8/x16
low-profile
x1/x4/x8/x16
low-profile
Note:
Always refer to the above configurations when installing a PCI riser-card assembly. Do not install a
PCI-riser card assembly that does not follow the above configurations.
The instructions in this section apply to any PCI adapter (for example, video graphics adapters or network
adapters).
To replace an adapter, complete the following steps:
Note:
If your adapter was previously configured, back up or record its configuration information, if possible,
before replacing the adapter. See the documentation for your adapter for information and instructions.
Step 1.
Read the safety information that begins on “Safety” on page v and “Installation guidelines” on
page 100.
Step 2.
Turn off the server and peripheral devices and disconnect the power cords and all external cables.
Step 3.
Remove the cover (see “Removing the cover” on page 104).
Removing and replacing components
127
Summary of Contents for HX1310
Page 1: ...HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide Machine Type 8693 ...
Page 6: ...iv HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Page 14: ...xii HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Page 984: ...970 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Page 994: ...980 HX1310 HX2310 E HX3310 HX3310 F Installation and Service Guide ...
Page 1001: ......
Page 1002: ......